background image

 

HP ProLiant DL320  

Generation 2 Server 

Setup and Installation Guide 

 

January 2003 (Second Edition) 

Part Number 293166-002 

This guide provides IT administrators and technicians setup and installation requirements, 
precautions, and instructions pertaining to the servers. The guide explains how to install 
hardware options for enhanced system performance, how to install and configure memory, 
how to install expansion boards, how to install the server in the rack, and how to cable and 
configure the servers. 

HP CONFIDENTIAL

 

Writer: Anna Roberts File Name: a-frnt.doc 

Codename: MoonStar Part Number: 293166-002 Last Saved On: 2/3/03 3:22 PM 

Содержание DL320 - ProLiant - G3

Страница 1: ...ecautions and instructions pertaining to the servers The guide explains how to install hardware options for enhanced system performance how to install and configure memory how to install expansion boards how to install the server in the rack and how to cable and configure the servers HP CONFIDENTIAL Writer Anna Roberts File Name a frnt doc Codename MoonStar Part Number 293166 002 Last Saved On 2 3...

Страница 2: ...warranty of any kind and is subject to change without notice The warranties for HP products are set forth in the express limited warranty statements accompanying such products Nothing herein should be construed as constituting an additional warranty HP ProLiant DL320 Generation 2 Server Setup and Installation Guide January 2003 Second Edition Part Number 293166 002 HP CONFIDENTIAL Writer Anna Robe...

Страница 3: ...r 1 Server Features HP ProLiant DL320 Generation 2 Server Features 1 1 Warranties 1 1 Server Configuration and Management 1 1 Security 1 2 Chapter 2 Planning the Server Installation Server Installation Overview 2 1 Optimum Environment 2 2 Space and Airflow Requirements 2 2 Temperature Requirements 2 4 HP ProLiant DL320 Generation 2 Server Setup and Installation Guide iii HP CONFIDENTIAL Writer Ann...

Страница 4: ...nstalling Hard Drives 3 18 Installing ATA Hard Drives 3 18 Installing SCSI Hard Drives 3 26 Installing a Slotless SCSI Module Upgrade Kit 3 27 External Mass Storage 3 30 Chapter 4 Server Installation Server Installation Procedures 4 1 Measuring with the Template 4 1 Installing the Fixed Rack Rails 4 3 Attaching the Fixed Cable Tray 4 4 Installing the Cable Support Bracket on the Server 4 5 Inserti...

Страница 5: ...y 5 6 Enterprise Diagnostics LX32 Utility 5 7 Automatic Server Recovery 5 7 Power On Self Test 5 7 System Firmware Update 5 8 Auto Configuration Process 5 8 Boot Options 5 9 System Maintenance Menu 5 9 Integrated Management Log 5 9 Chapter 6 RAID Configuration and Management Introduction to RAID 6 1 Overview of RAID 6 1 RAID Terminology 6 2 Integrated ATA RAID Configuration Utility 6 3 Configurati...

Страница 6: ...les A 3 Canadian Notice Avis Canadien A 4 Class A Equipment A 4 Class B Equipment A 4 European Union Notice A 4 Japanese Notice A 5 BSMI Notice A 5 Laser Devices A 5 Laser Safety Warnings A 6 Compliance with CDRH Regulations A 6 Compliance with International Regulations A 6 Laser Product Label A 6 Laser Information A 7 Battery Replacement Notice A 7 Power Cords A 8 Mouse Compliance Statement A 8 A...

Страница 7: ...Identification Switches E 7 Switches E 7 System Configuration Switch SW1 E 8 Clearing and Resetting System Password Settings E 10 Clearing and Resetting System Configuration Settings E 10 Setting the NIC Operating Mode E 11 Appendix F Server Specifications Operating and Performance Specifications F 1 Appendix G System Battery System Battery Replacement G 1 Index HP ProLiant DL320 Generation 2 Serv...

Страница 8: ...lling this product read the Important Safety Information document provided Symbols on Equipment The following symbols may be placed on equipment to indicate the presence of potentially hazardous conditions WARNING This symbol in conjunction with any of the following symbols indicates the presence of a potential hazard The potential for injury exists if warnings are not observed Consult your docume...

Страница 9: ...This symbol indicates the presence of a hot surface or hot component If this surface is contacted the potential for injury exists WARNING To reduce the risk of injury from a hot component allow the surface to cool before touching These symbols on power supplies or systems indicate that the equipment is supplied by multiple sources of power WARNING To reduce the risk of injury from electric shock r...

Страница 10: ...in the text of this guide They have the following meanings WARNING Text set off in this manner indicates that failure to follow directions in the warning could result in bodily harm or loss of life CAUTION Text set off in this manner indicates that failure to follow directions could result in damage to equipment or loss of information IMPORTANT Text set off in this manner presents clarifying infor...

Страница 11: ...pics covered in this guide refer to the following documentation HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide ProLiant Servers Cabling Matrix www hp com HP ProLiant DL320 Generation 2 Server Hardware Installation and Configuration Poster Servers Troubleshooting Guide www compaq com support home index asp Reference Library HP ProLiant DL320 Generation 2 Server High Density Dep...

Страница 12: ...st HP Technical Support Phone Center For telephone numbers of worldwide Technical Support Centers go to www hp com Before calling refer to the Servers Troubleshooting Guide for a list of information to have available HP Website For information on this product as well as the latest drivers and flash ROM images go to www hp com HP Authorized Reseller For the name of your nearest HP authorized resell...

Страница 13: ...veral standard warranties For more information refer to the Important Warranty Information card shipped with the server Server Configuration and Management The server offers an extensive set of features and optional tools to support effective server management and configuration Refer to Chapter 5 Server Configuration and Utilities for detailed information on each of these utilities HP ProLiant DL3...

Страница 14: ...es for this server include the following Power on password Administrator password Network server mode Diskette write control QuickLock Redundant ROM support Most security features are established through RBSU Refer to Chapter 5 Server Configuration and Utilities or the ROM Based Setup Utility User Guide for detailed information on RBSU For additional information concerning server security features...

Страница 15: ...Chapter 3 Installing Hardware Options Other options include additional memory hard drives expansion boards and external storage devices Install hardware options before running the System Configuration Utility The System Configuration Utility is run during the SmartStart portion of the installation sequence IMPORTANT Do not attempt to change the factory settings for reserved switches Inaccurate set...

Страница 16: ...he power cord and peripheral device cables in the fixed cable tray Refer to Securing the Cables in the Fixed Cable Tray in Chapter 4 Server Installation Optimum Environment When installing these servers in a rack select a location that meets the environmental standards described in the following paragraphs Space and Airflow Requirements To allow for servicing and adequate airflow observe the follo...

Страница 17: ...en using a Compaq branded 7000 Series rack the high airflow rack door insert must be installed P N 327281 B21 42U and P N 157847 B21 22U to provide proper front to back airflow and cooling CAUTION If a third party rack is used observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment Front and rear doors if the 42U server rack includes closing ...

Страница 18: ...installation of information technology equipment by licensed electricians This equipment is designed to operate in installations covered by NFPA 70 1999 Edition National Electric Code and NFPA 75 1992 Edition code for Protection of Electronic Computer Data Processing Equipment For electrical power ratings on options refer to the product s rating label or the user documentation supplied with that o...

Страница 19: ...nds the use of a power distribution unit PDU that is either permanently wired to the building s branch circuit or includes a non detachable cord that is wired to an industrial style plug NEMA locking style plugs or those complying with IEC 60309 are considered suitable for this purpose HP does not recommend using common power outlet strips for this equipment Rack Planning Resources For Rack Builde...

Страница 20: ...igh as much as 115 kg 253 lb can stand more than 2 1 m 7 ft tall and may become unstable when moved on its casters Never stand in front of the rack when it is rolling down the ramp from the pallet always handle the rack from both sides CAUTION Always begin by mounting the heaviest item on the bottom of the rack Continue to populate the rack from the bottom to the top Server Warnings and Cautions B...

Страница 21: ...erver from power fluctuations and temporary interruptions with a regulating uninterruptible power supply UPS This device protects the hardware from damage caused by power surges and voltage spikes and keeps the system in operation during a power failure CAUTION Do not operate the server for long periods without the access panel Operating the server without the access panel results in improper airf...

Страница 22: ...o the inside of the server access panel To streamline the installation process read the installation instructions for all of the hardware options and identify similar steps before beginning installation After installing all hardware options proceed with the server installation procedures in Chapter 4 Server Installation HP ProLiant DL320 Generation 2 Server Setup and Installation Guide 3 1 HP CONF...

Страница 23: ... is disconnected from the server or the electrical outlet CAUTION Electrostatic discharge can damage electronic components Be sure you are properly grounded before beginning any installation procedure To remove the access panel 1 Press and hold down the locking latches on each side of the access panel 2 Slide the access panel toward the rear of the unit about 1 25 cm 0 5 inch and lift the panel to...

Страница 24: ...nt and rear panels 2 c Press the server Power On Off switch 3 to power down the server The LED 4 changes from green to amber indicating standby mode Figure 3 1 Activating the front unit identification LED and powering down the server 2 When the server has a sliding rail solution a Loosen the thumbscrews securing the server in the rack b Slide the server out of the rack until the rail locks engage ...

Страница 25: ...s extending from expansion boards moving from left to right b Loosen the server thumbscrew securing the fixed cable tray to the server Figure 3 2 Loosening the server thumbscrew that secures the fixed cable tray to the server 3 4 HP ProLiant DL320 Generation 2 Server Setup and Installation Guide HP CONFIDENTIAL Writer Anna Roberts File Name d ch3 Installing Hardware Options doc Codename MoonStar P...

Страница 26: ... f Holding the rail release latches extend the server until the latches clear the rack g Pull the server completely out of the rack 3 and set it on a flat level surface Figure 3 3 Removing the server from the rack 4 Remove the access panel Refer to the Removing the Access Panel section earlier in this chapter HP ProLiant DL320 Generation 2 Server Setup and Installation Guide 3 5 HP CONFIDENTIAL Wr...

Страница 27: ... 2 2 Serial top and video bottom connectors 8 64 bit 33 MHz PCI riser board assembly connector 3 Mouse top and keyboard bottom connectors 9 System configuration switch SW1 4 RJ 45 fast Ethernet connectors for NIC 1 bottom and NIC 2 top 10 ATA controller secondary 5 Slotless SCSI module slot 11 Power connector 6 USB connector 1 12 System battery continued 3 6 HP ProLiant DL320 Generation 2 Server S...

Страница 28: ...t numbers This information is also available on the hood label The server memory can be expanded to 4 GB In the maximum memory configuration all four DIMM sockets are populated with 1 GB PC2100 ECC registered DDR SDRAM DIMMs Observe the following guidelines when installing additional memory DIMMs installed in the server must be PC2100 registered DDR SDRAM 2 5 V 64 bits wide and ECC All DIMMs insta...

Страница 29: ...Align the key slot in the bottom edge of the DIMM with the tab in the expansion socket IMPORTANT Misaligned DIMMs do not seat 4 Press down firmly on the DIMM while pushing the latches inward until the latches snap into place 5 Reverse the procedures performed in the Accessing Internal Server Components section earlier in this chapter Installing an Expansion Board To install an expansion board comp...

Страница 30: ...ternal server components Refer to the Accessing Internal Server Components section earlier in this chapter 2 Disconnect any cables leading from any existing expansion board in the system board 3 Loosen the PCI riser board thumbscrew 1 4 Lift the assembly from the server chassis 2 Figure 3 5 Removing the PCI riser board assembly expansion board removed for clarity HP ProLiant DL320 Generation 2 Ser...

Страница 31: ...ver CAUTION Do not discard the expansion slot cover If the PCI expansion board is removed in the future the expansion slot cover must be reinstalled to maintain proper cooling 3 10 HP ProLiant DL320 Generation 2 Server Setup and Installation Guide HP CONFIDENTIAL Writer Anna Roberts File Name d ch3 Installing Hardware Options doc Codename MoonStar Part Number 293166 002 Last Saved On 1 31 03 11 16...

Страница 32: ...n board into the expansion slot IMPORTANT If the expansion board ships with an ISA extender bracket remove it from the expansion board before inserting the board into the expansion slot of the PCI riser board assembly HP ProLiant DL320 Generation 2 Server Setup and Installation Guide 3 11 HP CONFIDENTIAL Writer Anna Roberts File Name d ch3 Installing Hardware Options doc Codename MoonStar Part Num...

Страница 33: ...ly with the retainers 2 on the rear panel of the chassis Figure 3 8 Aligning the tabs of the PCI riser board assembly with the rear panel of the chassis 3 12 HP ProLiant DL320 Generation 2 Server Setup and Installation Guide HP CONFIDENTIAL Writer Anna Roberts File Name d ch3 Installing Hardware Options doc Codename MoonStar Part Number 293166 002 Last Saved On 1 31 03 11 16 AM ...

Страница 34: ... PCI riser board assembly is not properly seated d Tighten the PCI riser board thumbscrew 2 Figure 3 9 Installing the PCI riser board assembly HP ProLiant DL320 Generation 2 Server Setup and Installation Guide 3 13 HP CONFIDENTIAL Writer Anna Roberts File Name d ch3 Installing Hardware Options doc Codename MoonStar Part Number 293166 002 Last Saved On 1 31 03 11 16 AM ...

Страница 35: ...tem board To complete external cabling and setup refer to the Cabling the Remote Insight Lights Out Edition II Optional section in Chapter 4 Server Installation Figure 3 10 Cabling the Remote Insight Lights Out Edition II to the system board 3 14 HP ProLiant DL320 Generation 2 Server Setup and Installation Guide HP CONFIDENTIAL Writer Anna Roberts File Name d ch3 Installing Hardware Options doc Co...

Страница 36: ...server Figure 3 11 Smart Array controller cabled to SCSI hard drives c To cable other expansion boards refer to the instructions included with the board 5 Reverse the procedures performed in the Accessing Internal Server Components section earlier in this chapter Installing a CD ROM diskette or DVD ROM diskette Drive Assembly Optional The CD ROM diskette drive and the DVD ROM diskette drive proced...

Страница 37: ...m the inside of the server or if the key was previously removed go to step 2 NOTE The shipping ejector key secures either the CD ROM diskette or DVD ROM diskette drive assembly or the bezel blank during shipping It is also used to eject the assembly or the blank a Access internal server components Refer to the Accessing Internal Server Components section earlier in this chapter b Remove the shippi...

Страница 38: ... Figure 3 13 Ejecting the bezel blank NOTE If you intend to use the CD ROM diskette or DVD ROM diskette drive assembly ejection feature frequently leave the shipping ejector key in the ejector port for easy access Otherwise store the shipping ejector key for future use HP ProLiant DL320 Generation 2 Server Setup and Installation Guide 3 17 HP CONFIDENTIAL Writer Anna Roberts File Name d ch3 Instal...

Страница 39: ...ly can be removed for use in another ProLiant DL320 Generation 2 server or to prevent unwanted software installation Installing Hard Drives Optional mass storage devices can be connected to the server through the optional SCSI module or an array controller expansion board Installing ATA Hard Drives This server model comes pre configured for two 1 inch ATA hard drives and has two ATA channels 3 18 ...

Страница 40: ...hard drives may damage the system by consuming power and generating heat in excess of the server s operating tolerance This condition may result in a loss of system and or data integrity CAUTION When supporting a mixed environment of ATA drives and SCSI drives in the server the ATA drive must be the boot device ATA hard drives installed in the server appear as Devices 0 and 1 from left to right wh...

Страница 41: ...recommended that all server data be backed up to avoid loss 3 Remove the PCI riser board assembly Refer to the Removing the PCI Riser Board Assembly section earlier in this chapter 4 Remove the center wall Use the following procedure to remove the center wall a Disconnect the center wall fan cables from the fan connectors on the system board Figure 3 15 Disconnecting the center wall fan cables 3 2...

Страница 42: ...chassis 2 d Raise the locking end of the center wall from the chassis 3 Figure 3 16 Unlocking the center wall HP ProLiant DL320 Generation 2 Server Setup and Installation Guide 3 21 HP CONFIDENTIAL Writer Anna Roberts File Name d ch3 Installing Hardware Options doc Codename MoonStar Part Number 293166 002 Last Saved On 1 31 03 11 16 AM ...

Страница 43: ...gnment tab from the alignment slot 5 Identify the tray into which the ATA hard drive is to be installed 3 22 HP ProLiant DL320 Generation 2 Server Setup and Installation Guide HP CONFIDENTIAL Writer Anna Roberts File Name d ch3 Installing Hardware Options doc Codename MoonStar Part Number 293166 002 Last Saved On 1 31 03 11 16 AM ...

Страница 44: ...These servers ship with the ATA cables already installed The module cables are threaded through the opening in the center wall and are connected to the ATA module The device connectors lay in the hard drive bay HP ProLiant DL320 Generation 2 Server Setup and Installation Guide 3 23 HP CONFIDENTIAL Writer Anna Roberts File Name d ch3 Installing Hardware Options doc Codename MoonStar Part Number 293...

Страница 45: ...ith the data and power connectors along the bottom of the tray and facing away from the front grill NOTE The Phillips screws for this operation are shipped along the top edge of the PCI riser board assembly 3 24 HP ProLiant DL320 Generation 2 Server Setup and Installation Guide HP CONFIDENTIAL Writer Anna Roberts File Name d ch3 Installing Hardware Options doc Codename MoonStar Part Number 293166 ...

Страница 46: ...through 8 to install a second ATA hard drive 10 Connect the ATA cables as shown below Figure 3 21 Cabling the ATA hard drives 11 Connect the hard drive power cable to the ATA hard drives HP ProLiant DL320 Generation 2 Server Setup and Installation Guide 3 25 HP CONFIDENTIAL Writer Anna Roberts File Name d ch3 Installing Hardware Options doc Codename MoonStar Part Number 293166 002 Last Saved On 1 ...

Страница 47: ... may damage the system by consuming power and generating heat in excess of the server s operating tolerance This condition may result in a loss of system and or data integrity Each SCSI hard drive must be assigned a unique ID The system begins searching the drive with the lowest numbered ID for a bootable partition The jumpers on a factory installed hard drive are set to ID 0 For illustration purp...

Страница 48: ...d from the front of the server 4 Set the jumpers for the SCSI device Refer to the instructions that shipped with the SCSI hard drive 5 Reverse the steps in Accessing Internal Server Components earlier in this chapter Installing a Slotless SCSI Module Upgrade Kit This server supports the addition to the system board of a single channel slotless SCSI module Once installed SCSI hard drives can be add...

Страница 49: ... for later use Refer to Figure 3 21 5 Remove the ATA hard drives if necessary 6 Insert the SCSI module stand offs Figure 3 22 Inserting the SCSI Module stand offs 3 28 HP ProLiant DL320 Generation 2 Server Setup and Installation Guide HP CONFIDENTIAL Writer Anna Roberts File Name d ch3 Installing Hardware Options doc Codename MoonStar Part Number 293166 002 Last Saved On 1 31 03 11 16 AM ...

Страница 50: ...ard Figure 3 23 Installing the SCSI module into the SCSI module slot HP ProLiant DL320 Generation 2 Server Setup and Installation Guide 3 29 HP CONFIDENTIAL Writer Anna Roberts File Name d ch3 Installing Hardware Options doc Codename MoonStar Part Number 293166 002 Last Saved On 1 31 03 11 16 AM ...

Страница 51: ...es 4 to the SCSI hard drives 3 11 Install the center wall and PCI riser board assembly Be sure that the cables run through the opening in the center wall 2 Figure 3 24 Cable configuration of the slotless SCSI module 12 Install the access panel 13 Configure any devices attached to the SCSI module before powering up the server Refer to the documentation that ships with the slotless SCSI module upgra...

Страница 52: ... secure the server faceplate to the front of the rack CAUTION Always mount the heaviest item on the bottom of the rack and work from the bottom to the top IMPORTANT Determine the server s place in the rack before starting installation of the fixed rack rails Refer to the Rack Builder report that was printed during planning of the rack configuration HP ProLiant DL320 Generation 2 Server Setup and I...

Страница 53: ... rack Figure 4 1 Measuring with the template 2 Align the template so that the sides of the template are squared up with the sides of the rack Tick marks on the rack s vertical rails help maintain the proper alignment The tick marks allow identification of the U spaces 4 2 HP ProLiant DL320 Generation 2 Server Setup and Installation Guide HP CONFIDENTIAL Writer Anna Roberts File Name e ch4 Server I...

Страница 54: ...ar of the rack remove the template from the rack Attach the fixed rack rails to the rack Refer to the Installing the Fixed Rack Rails section in this chapter Installing the Fixed Rack Rails Use the following procedures to install the fixed rack rails to the rack 1 Measure with the template Refer to Measuring with the Template earlier in this chapter 2 From the rear of the rack identify the inside ...

Страница 55: ...gned with the inner holes at the back of the rack 6 Insert the rear tabs into the rear holes and release the rail The rail should lock in place securely 7 Repeat steps 2 through 6 for the second fixed rack rail After both fixed rack rails are installed begin the procedure for Attaching the Fixed Cable Tray Attaching the Fixed Cable Tray Use the following procedure to attach the fixed cable tray 1 ...

Страница 56: ... Cable Support Bracket enables the use of the rack management solutions available for this server Use the following procedure to attach the Cable Support Bracket 1 Access internal server components Refer to the Accessing Internal Server Components section in Chapter 3 Installing Hardware Options HP ProLiant DL320 Generation 2 Server Setup and Installation Guide 4 5 HP CONFIDENTIAL Writer Anna Robe...

Страница 57: ...ar panel 2 Figure 4 5 Installing the cable support bracket 3 Reverse procedures performed in the Accessing Internal Server Components section in Chapter 3 Installing Hardware Options 4 6 HP ProLiant DL320 Generation 2 Server Setup and Installation Guide HP CONFIDENTIAL Writer Anna Roberts File Name e ch4 Server Installation doc Codename MoonStar Part Number 293166 002 Last Saved On 1 31 03 11 17 A...

Страница 58: ...il release latches and slowly slide the server into the rack The rail release latches can pinch your fingertips 2 Insert the server fully into the rack ensuring that the fixed server rails slide inside the fixed rack rails CAUTION Keep the server parallel to the floor when sliding the fixed server rails into the slide rails Tilting the server can damage the rails 3 Tighten the thumbscrews on the f...

Страница 59: ...ION If the Remote Insight Lights Out Edition II RILOE II is installed in the server be sure that you attach the video cable to the video connector on the rear of the RILOE II board The standard video connector on the server rear panel is not used when the RILOE II is installed For more information refer to the Remote Insight Lights Out Edition II User Guide Use the following figure and table to id...

Страница 60: ... connector RILOE II 4 Video connector RILOE II 5 AC adapter connector RILOE II 6 RJ 45 Fast Ethernet connector for NIC 2 7 RJ 45 Fast Ethernet connector for NIC 1 supports PXE 8 Mouse connector 9 Serial connector 10 Video connector 11 Keyboard connector continued HP ProLiant DL320 Generation 2 Server Setup and Installation Guide 4 9 HP CONFIDENTIAL Writer Anna Roberts File Name e ch4 Server Instal...

Страница 61: ...te Insight Lights Out Edition II RILOE II refer to the Remote Insight Lights Out Edition II User Guide included with the option kit or refer to www compaq com manage remote lightsout html 1 Locate the external connectors on the rear panel of the server in the expansion bay Refer to Figure 4 8 and Table 4 1 2 Disconnect the video cable from the video connector on the rear of the server 4 10 HP ProL...

Страница 62: ...er s high density design may prevent some video cables from fully seating on the Remote Insight Lights Out Edition II However the design does support video cables with a height that is less than or equal to 1 57 cm 0 62 inch HP ProLiant DL320 Generation 2 Server Setup and Installation Guide 4 11 HP CONFIDENTIAL Writer Anna Roberts File Name e ch4 Server Installation doc Codename MoonStar Part Numb...

Страница 63: ...the RJ 45 connector on the RILOE II The standard RJ 45 connectors on the server rear panel do not provide network access to the RILOE II Securing the Cables in the Fixed Cable Tray After attaching the fixed cable tray and cable support bracket and connecting the peripheral devices and power cord secure all cabling 4 12 HP ProLiant DL320 Generation 2 Server Setup and Installation Guide HP CONFIDENT...

Страница 64: ...g the cable clamp cables shortened for clarity 2 Starting with the peripheral device cables on the left route all of the cables and cords into the cable clamp HP ProLiant DL320 Generation 2 Server Setup and Installation Guide 4 13 HP CONFIDENTIAL Writer Anna Roberts File Name e ch4 Server Installation doc Codename MoonStar Part Number 293166 002 Last Saved On 1 31 03 11 17 AM ...

Страница 65: ...oute the cables to the side of the rack Refer to Figure 4 13 for an example Figure 4 13 Multiple servers installed in a rack with properly routed cabling 4 14 HP ProLiant DL320 Generation 2 Server Setup and Installation Guide HP CONFIDENTIAL Writer Anna Roberts File Name e ch4 Server Installation doc Codename MoonStar Part Number 293166 002 Last Saved On 1 31 03 11 17 AM ...

Страница 66: ... instructions on the SmartStart and Support Software CD Refer to the Server Setup and Management pack for instructions on using SmartStart software The first time the server is configured the SmartStart software automatically creates a necessary partition on the hard drive This partition cannot be used for any other purpose and is not a traditional system partition When setting up the server for t...

Страница 67: ... Configuration and Utilities 3 Run the ROM Based Setup Utility RBSU by pressing the F9 key when prompted Use RBSU to identify the type of operating system and set the date and time For information on using the RBSU to configure other server features refer to Chapter 5 Server Configuration and Utilities 4 Install the operating system 5 Install Insight Manager to manage the server For Management CD ...

Страница 68: ...verything required to install the operating system is already on the server Refer to the steps provided in the HP Factory Installed Operating System Software User Guide for more information on using the operating system To complete the installation process with a pre configured operating system 1 Power up the server Refer to Powering Up the Server earlier in this chapter 2 Follow the on screen ins...

Страница 69: ...on CD included in the Reference Information pack shipped with the server Optional Installation Service HP offers an optional installation service for installing rack products The installation service can be customized to meet the specific requirements of the customer or it can be ordered as a CarePaq The installation service covers the entire hardware installation process from unpacking the compon...

Страница 70: ... guide refer to the HP ROM Based Setup Utility User Guide found in the ProLiant Essentials Foundation pack Redundant ROM Support The user can upgrade or configure the ROM safely due to the redundant ROM support feature The server has a 2 MB ROM that acts as two separate 1 MB ROMs In the standard implementation one side of the ROM contains the current ROM program version while the other side of the...

Страница 71: ...press the F10 key to exit RBSU 6 Restart the server When the server boots the system identifies whether the current ROM bank is corrupt If a corrupt ROM is detected the system boots from the backup ROM and alerts the user through POST that the ROM bank is corrupt Switching ROM images in the event that the RBSU is inaccessible can also be done by changing the switch settings on the system configura...

Страница 72: ...em ROM images At the successful completion of this process a sequence of ascending audible beeps tone is generated If the flash is not successful a sequence of descending audible beeps is generated 5 After successful completion of this process a Power down the server b Remove the ROMPaq diskette c Power up the server as usual If the ROMPaq upgrade procedure was unsuccessful power down the server a...

Страница 73: ...test optimized drivers Create and copy standard server configuration scripts using the Scripting Toolkit and Configuration Replication Utility Test server hardware using the new Enterprise Diagnostics LX32 Utility Update the latest system or option ROM using the ROM Update Utility Access software drivers through creation of diskettes or installation directly from the CD With systems that have inte...

Страница 74: ...S DOS based utilities that enable the user to configure and deploy servers in a customized predictable and unattended manner These utilities provide scripted server and array replication for mass server deployment and duplicate the configuration of a source server onto target systems with minimum user interaction The Configuration Replication Utility is a stand alone MS DOS utility that duplicates...

Страница 75: ... information gathering agent for Microsoft Windows Novell NetWare and Linux operating systems that collects critical hardware and software information from various sources If a significant change occurs between data gathering intervals the previous information is marked and the data file is overwritten to reflect the latest configuration and changes This file allows the user to keep a historical r...

Страница 76: ...em failure the timer expires and restarts the server ASR increases server up time by restarting the server within a predetermined amount of time after the system stops responding The Insight Manager console notifies the user in the event of an ASR restart The user can disable ASR from the Insight Manager console IMPORTANT The System Management driver must be installed for ASR to function Power On ...

Страница 77: ...rst time During the power up sequence that occurs the system ROM automatically configures the system with defaults without needing any intervention By default the auto configuration process configures the system for the Microsoft Windows 2000 operating system To change any default settings in the auto configuration process such as the settings for language operating system and primary boot control...

Страница 78: ...eplaces the legacy system partition functionality supported on some HP servers To access the System Maintenance Menu press the F10 key when prompted from the boot option screen For more information on using the features of the System Maintenance Menu refer to the HP ROM Based Setup Utility User Guide Integrated Management Log The Integrated Management Log IML records hundreds of events and stores ...

Страница 79: ...CONFIDENTIAL Writer Anna Roberts File Name f ch5 Server Configuration and Utilities doc Codename MoonStar Part Number 293166 002 Last Saved On 1 31 03 11 18 AM For more information refer to the Servers Troubleshooting Guide on the Documentation CD or the Management CD in the ProLiant Essentials Foundation Pack ...

Страница 80: ...e accessed simultaneously improving I O input output performance The RAID array is recognized by the host computer as a single storage unit or as multiple logical units Data loss because of a drive failure can be prevented for RAID 1 and RAID 1 0 by reconstructing missing data from the remaining data drives HP ProLiant DL320 Generation 2 Server Setup and Installation Guide 6 1 HP CONFIDENTIAL Writ...

Страница 81: ...D 1 RAID 1 0 RAID 1 0 is not supported by the ProLiant DL320 Generation 2 server or the Integrated ATA RAID Configuration Utility RAID 1 0 also known as RAID 10 is a RAID level that provides both striping and mirroring capabilities RAID 1 0 mirrors data from one drive to another and then stripes the data across a second set of drives Four hard drives are required to support RAID 1 0 on the server ...

Страница 82: ... equal to the failed drive it replaces Integrated ATA RAID Configuration Utility The Integrated ATA RAID Configuration Utility is a standard feature of ATA models of the server This section details the features of the utility including how to access and change utility options Configuration Utility Features The features of the Integrated ATA RAID Configuration Utility include the following Optimize...

Страница 83: ...e delete or edit the existing configurations Press the up arrow and down arrow keys to navigate the properties and then press the Enter key to edit your selection Additional arrays can be created in this window Refer to Chapter 2 of the HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide for more information NOTE To add additional arrays follow the onscreen steps after an array con...

Страница 84: ...s are lost when the Auto Configure option is run for RAID 0 RAID 1 and RAID 1 0 arrays Create Array F4 creates a drive array When this option is selected a default array template is created The array properties must be edited to complete the array creation Use the arrow keys to select a property field and then press the Enter key to edit that property The array properties are as follows Array Type...

Страница 85: ... F6 restores the configuration that was there before accessing the utility Edit Options F7 edits the physical drive option status boxes located in the top right corner of the Physical Drive Information window The options are as follows WC OFF enables or disables write cache CAUTION Enabling write cache may cause data loss or corruption during an unexpected loss of power DMA ON enables or disables ...

Страница 86: ...t OS Writing of array status to the console Netware OS Automatic rebuild of pre configured online spares following a RAID 1 failure Linux Netware and Microsoft OS Using the Management Utility Once installed and running no user intervention is required for the use of the Integrated ATA RAID Management Utility The utility runs automatically at boot time If the utility must be shut down for any reaso...

Страница 87: ...and the Integrated ATA RAID Configuration Utility Such is the case when a drive has failed in a RAID 1 or RAID 1 0 configuration The POST message will list the array as running in a Degraded state and the Integrated ATA RAID Configuration Utility will list it as being in a Rebuilding state If this inconsistency occurs the array must be rebuilt If drives are added to a configuration the Integrated ...

Страница 88: ...ected Noting the position of the drive and editing any arrays containing the newly added drive presented in the Integrated ATA RAID Configuration Utility Use the same type of drives or drives with similar capability in terms of speed and capacity Do not use dissimilar drives on the same channel Always use 80 conductor Ultra ATA cables Do not connect any ATAPI devices such as CD ZIP or LS120 to the...

Страница 89: ...1 19 AM 2 If an unexpected message is received such as Drives Missing or Configuration Mismatch switch off the server and check all connections ATA cables and power cables 3 If the Configuration Mismatch message is received after adding new drives that is because the new drives had been used before and the configuration on the drives was not cleared If this message is displayed press the F8 key to...

Страница 90: ...its to provide an interference free radio frequency spectrum Many electronic devices including computers generate RF energy incidental to their intended function and are therefore covered by these rules These rules place computers and related peripheral devices into two classes A and B depending upon their intended installation Class A devices are those that may reasonably be expected to be instal...

Страница 91: ...o comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications H...

Страница 92: ... declaration contact Hewlett Packard Company P O Box 692000 Mail Stop 510101 Houston Texas 77269 2000 or call 281 514 3333 To identify this product refer to the part series or model number found on the product Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Hewlett Packard Company may void the user s au...

Страница 93: ...rking comply with the EMC Directive 89 336 EEC and the Low Voltage Directive 73 23 EEC issued by the Commission of the European Community and if this product has telecommunication functionality the R TTE Directive 1999 5 EC Compliance with these directives implies conformity to the following European Norms in parentheses are the equivalent international standards and regulations EN 55022 CISPR 22 ...

Страница 94: ... the equipment complies with laser product performance standards set by government agencies as a Class 1 laser product The product does not emit hazardous light the beam is totally enclosed during all modes of customer operation and maintenance HP ProLiant DL320 Generation 2 Server Setup and Installation Guide A 5 HP CONFIDENTIAL Writer Anna Roberts File Name k appa Regulatory Compliance Notices d...

Страница 95: ...t 2 1976 These regulations apply to laser products manufactured from August 1 1976 Compliance is mandatory for products marketed in the United States Compliance with International Regulations All HP systems equipped with laser devices comply with appropriate safety standards including IEC 825 Laser Product Label The following label or equivalent is located on the surface of the HP supplied laser d...

Страница 96: ...P authorized reseller or your authorized service provider WARNING This server contains an internal Lithium Manganese Dioxide or a Vanadium Pentoxide or an alkaline battery pack There is risk of fire and burns if the battery pack is not handled properly To reduce the risk of personal injury Do not attempt to recharge the battery Do not expose to temperatures higher than 60 C Do not disassemble crus...

Страница 97: ...be rated for the product and for the voltage and current marked on the product s electrical ratings label The voltage and current rating of the cord should be greater than the voltage and current rating marked on the product In addition the diameter of the wire must be a minimum of 1 00 mm or 18 AWG and the length of the cord must be between 1 8 m 6 feet and 3 6 m 12 feet If you have questions abo...

Страница 98: ...void hand contact by transporting and storing products in static safe containers Keep electrostatic sensitive parts in their containers until they arrive at static free workstations Place parts on a grounded surface before removing them from their containers Avoid touching pins leads or circuitry Always be properly grounded when touching a static sensitive component or assembly HP ProLiant DL320 G...

Страница 99: ...mputer chassis Wrist straps are flexible straps with a minimum of 1 megaohm 10 percent resistance in the ground cords To provide proper grounding wear the strap snug against the skin Use heel straps toe straps or boot straps at standing workstations Wear the straps on both feet when standing on conductive floors or dissipating floor mats Use conductive field service tools Use a portable field serv...

Страница 100: ...rs Troubleshooting Guide also included on the documentation CD HP ProLiant DL320 Generation 2 Server Setup and Installation Guide C 1 HP CONFIDENTIAL Writer Anna Roberts File Name m appc Server Error Messages doc Codename MoonStar Part Number 293166 002 Last Saved On 1 31 03 11 21 AM ...

Страница 101: ...EDs Switches and Jumpers For information about general troubleshooting techniques diagnostic tools preventative maintenance and a complete list of error messages refer to the Servers Troubleshooting Guide also included on the documentation CD HP ProLiant DL320 Generation 2 Server Setup and Installation Guide D 1 HP CONFIDENTIAL Writer Anna Roberts File Name n appd Troubleshooting doc Codename Moon...

Страница 102: ...re plugged into a working outlet 2 Be sure that the power source is working properly Confirm status using the Power On Standby LED Refer to System Board LEDs in Appendix E for the location and status of the Power On Standby LED Confirm that the Power On Standby switch was pressed firmly Refer to the Servers Troubleshooting Guide for details on what else to evaluate 3 If the system does not complet...

Страница 103: ...ollowing sequence Video initialization The initialization screen is displayed Processor initialization Memory test Memory initialization Diskette drive SCSI devices if applicable ATA devices if applicable Option ROM d The operating system loads to complete the boot process If the problem persists continue with the section Diagnosis Steps in this appendix HP ProLiant DL320 Generation 2 Server Setup...

Страница 104: ...o Question 4 Question 2 Is the front panel Internal Health LED red If no go to Table D 2 and then continue to Question 3 if the problem is not solved If yes continue to Question 4 Question 3 Are any system board LEDs showing a failure or error condition Refer to Appendix E LEDs Switches and Jumpers for the location and status information of all system board LEDs If no go to Question 4 If yes then ...

Страница 105: ...d error messages Refer to the Servers Troubleshooting Guide for a complete description of each POST error message NOTE If the server attempts to load the operating system go to Problems After Initial Startup in this appendix HP ProLiant DL320 Generation 2 Server Setup and Installation Guide D 5 HP CONFIDENTIAL Writer Anna Roberts File Name n appd Troubleshooting doc Codename MoonStar Part Number 2...

Страница 106: ...r options 4 Reconnect the power button cable to the system board Refer to Chapter 3 Installing Hardware Options for the location of the power button connector 5 Power down the server Reseat all expansion boards DIMMs processors and PPMs Reseat all cable connections Refer to Chapter 3 Installing Hardware Options for complete instructions Refer to the Servers Troubleshooting Guide for tips on proper...

Страница 107: ...ards or DIMMs may not be properly connected or seated 1 Be sure that the monitor has power and that the monitor cable is securely connected If more than one video adapter is installed make sure that the monitor is connected to the correct video board 2 Be sure that the monitor is functional by connecting it to a known working server 3 Be sure that the switch settings on the system board are correc...

Страница 108: ... error messages 7 Monitor the diagnostic LEDs on the system board for failure conditions 8 Refer to the Servers Troubleshooting Guide for more information on video problems 9 If these steps do not correct the problem contact an authorized service provider for further technical support D 8 HP ProLiant DL320 Generation 2 Server Setup and Installation Guide HP CONFIDENTIAL Writer Anna Roberts File Na...

Страница 109: ...overy ASR power up caused by another problem Review Insight Manager for notification of this event Refer to the Servers Troubleshooting Guide for more information Refer to the Servers Troubleshooting Guide for the following Information that must be collected when diagnosing software problems and to provide when contacting support Instructions on how to upgrade the operating system and its drivers ...

Страница 110: ...ete instructions on the use of RBSU The CD ROM diskette or DVD ROM diskette drive assembly is either not installed or is not properly connected 1 Power down the server 2 Ensure that the CD ROM diskette or DVD ROM diskette drive assembly is installed 3 Remove and reseat the CD ROM diskette or DVD ROM diskette drive assembly 4 Reseat the cable between the backplane and the CD ROM diskette or DVD ROM...

Страница 111: ...n all connected hard drives Read System Erase Utility and the associated cautionary statements in the Servers Troubleshooting Guide before performing this operation Server cannot load operating system Required operating system step was missed Follow these steps 1 Note at which phase the operating system failed 2 Remove any loaded operating system components 3 Refer to the operating system document...

Страница 112: ...m software installation must be completed before adding new hardware to the system Be sure that all instructions provided in the HP Factory Installed Operating System Software Installation Guide are being followed Remove the new hardware and complete the software installation Then reinstall the new hardware Note Refer to Chapter 5 Server Configuration and Utilities or refer to the HP ROM Based Set...

Страница 113: ...general hardware and software troubleshooting information for all HP ProLiant servers a complete list of error messages along with an explanation of probable cause and a list of appropriate measures This guide ships with the server HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide This resource provides a complete list of all replacement parts available along with step by step in...

Страница 114: ...sections to determine the location and status of LEDs on the server Front Panel LED Indicators The set of seven LEDs on the front of the server indicates server status The following figure and table identify and describe the location and function of the LEDs HP ProLiant DL320 Generation 2 Server Setup and Installation Guide E 1 HP CONFIDENTIAL Writer Anna Roberts File Name o appe LEDs Switches and...

Страница 115: ... Deactivated 2 NIC 2 link activity On Link Off No Link Blinking Activity 3 NIC 1 link activity On Link Off No Link Blinking Activity 4 System health Green Good Amber Degraded Red Critical Error continued E 2 HP ProLiant DL320 Generation 2 Server Setup and Installation Guide HP CONFIDENTIAL Writer Anna Roberts File Name o appe LEDs Switches and Jumpers doc Codename MoonStar Part Number 293166 002 L...

Страница 116: ...r On Off Green Power On Amber Standby mode Off Power Off 7 CD ROM diskette or DVD ROM diskette drive activity On Activity Off No Activity HP ProLiant DL320 Generation 2 Server Setup and Installation Guide E 3 HP CONFIDENTIAL Writer Anna Roberts File Name o appe LEDs Switches and Jumpers doc Codename MoonStar Part Number 293166 002 Last Saved On 1 31 03 11 22 AM ...

Страница 117: ...ifying the rear panel LED indicators Table E 2 Rear Panel LED Indicators Location LED Status 1 NIC 1 link activity On Link Off No Link Blinking Activity 2 NIC 2 link activity On Link Off No Link Blinking Activity continued E 4 HP ProLiant DL320 Generation 2 Server Setup and Installation Guide HP CONFIDENTIAL Writer Anna Roberts File Name o appe LEDs Switches and Jumpers doc Codename MoonStar Part ...

Страница 118: ...m board contains various LEDs which display current conditions of the server These are identified in the illustration below and in Table E 3 Figure E 3 Locating the system board LEDs and switches HP ProLiant DL320 Generation 2 Server Setup and Installation Guide E 5 HP CONFIDENTIAL Writer Anna Roberts File Name o appe LEDs Switches and Jumpers doc Codename MoonStar Part Number 293166 002 Last Save...

Страница 119: ...perature critical 8 Fan 3 failure 9 Fan 4 failure 10 CPU power cable unplugged 11 DIMM 1 failure 12 DIMM 2 failure 13 DIMM 3 failure 14 DIMM 4 failure 15 System temperature alert 16 VRM failure E 6 HP ProLiant DL320 Generation 2 Server Setup and Installation Guide HP CONFIDENTIAL Writer Anna Roberts File Name o appe LEDs Switches and Jumpers doc Codename MoonStar Part Number 293166 002 Last Saved ...

Страница 120: ...itch LED 3 Power On Off switch 4 Unit Identification switch rear view Switches The system board contains a switchbank that may need to be modified to set configuration or to trigger special functions These switches can cause problems if they are not correctly set HP ProLiant DL320 Generation 2 Server Setup and Installation Guide E 7 HP CONFIDENTIAL Writer Anna Roberts File Name o appe LEDs Switche...

Страница 121: ...llowing subsections provide reference information about setting the system board switches and jumpers which is part of the reconfiguration process along with running the ROM Based Setup Utility RBSU System Configuration Switch SW1 The system configuration switch SW1 is an eight position switch used for system configuration Refer to the labels attached to the inside of the server access panel for t...

Страница 122: ...tting and enable floppy boot S5 Password override Off Open off Normal honor RBSU setting Closed on Override RBSU setting and override password prompts S6 Invalidate CMOS NVRAM Off Open off Normal Closed on BIOS will clear CMOS and NVRAM S7 Reserved Off S8 Reserved Off NOTE On activates the function HP ProLiant DL320 Generation 2 Server Setup and Installation Guide E 9 HP CONFIDENTIAL Writer Anna R...

Страница 123: ...ault Off position 6 Restart the server The password is cleared Clearing and Resetting System Configuration Settings It may be necessary at some time to clear and reset system configuration settings When the system switch position 6 is set to the On position the system is prepared to erase all system configuration settings from both CMOS and NVRAM IMPORTANT Clearing CMOS and or NVRAM deletes the co...

Страница 124: ... LEDs Switches and Jumpers doc Codename MoonStar Part Number 293166 002 Last Saved On 1 31 03 11 22 AM NOTE For complete instructions on how to use RBSU refer to Chapter 5 Setting the NIC Operating Mode The NIC operating modes do not have to be set because the controllers automatically differentiate between the 10 Mbit 100 Mbit and 1 GB environments ...

Страница 125: ...24 58 lb Input requirements Rated input voltage 100 VAC to 240 VAC Rated input frequency 50 Hz to 60 Hz Rated input current 2 8 A 110 V to 1 4 A 220 V Rated input power 307 W BTUs per hour 1048 continued HP ProLiant DL320 Generation 2 Server Setup and Installation Guide F 1 HP CONFIDENTIAL Writer Anna Roberts File Name p appf Server Specifications doc Codename MoonStar Part Number 293166 002 Last ...

Страница 126: ...supply output Rated steady state power 180 W Maximum peak power 200 W Temperature range Operating See note 10 C to 35 C 50 F to 95 F Shipping See note 40 C to 70 C 40 F to 158 F Relative humidity noncondensing Operating See note 10 to 90 Non operating See note 5 to 95 Maximum wet bulb temperature 28 C 82 4 F NOTE Operating temperature has an altitude derating of 1 C per 304 8 M 1 000 ft No direct ...

Страница 127: ... plug is an important safety feature Plug the power cord into a grounded earthed electrical outlet that is easily accessible at all times Disconnect power from the server or other product by unplugging the power cord from either the electrical outlet or the server or other product To install a new battery 1 Access internal server components Refer to Accessing Internal Server Components in Chapter ...

Страница 128: ...nstalling Hardware Options 4 Remove the existing battery Figure G 1 Removing the system battery 5 Install the new battery 6 If you removed the PCI riser board assembly in step 3 reinstall it Refer to Installing an Expansion Board in Chapter 3 Installing Hardware Options 7 Reverse the procedures performed in the Accessing Internal Server Components section in Chapter 3 Installing Hardware Options 8...

Страница 129: ...emoving 3 17 array See Integrated ATA RAID Configuration Utility BIOS See ROM See firmware blanking panels rack 2 3 ASR Automatic Server Recovery boards See expansion boards disabling 5 7 BSMI notice A 5 overview 5 7 power cycling D 2 D 9 ATA controllers connectors 3 6 C ATA hard drives cable clamp device numbers 3 19 closing 4 14 installation guidelines 3 19 opening 4 13 installing 3 20 thumbscre...

Страница 130: ...ouse location 4 9 starting server with SmartStart 4 17 PCI riser board assembly 3 6 System Erase Utility D 11 power cord location 4 10 CD ROM diskette drive rear panel connection order 4 9 connector location 3 7 rear panel described 4 9 4 10 ejector port 3 17 rear panel illustrated 4 8 installing 3 16 Remote Insight Lights Out Edition II 3 7 LED activity E 3 troubleshooting D 10 RJ 45 locations 4 ...

Страница 131: ...bleshooting D 12 disposal battery A 8 fan cables location 3 20 dissipating floor mats B 2 fan connectors location 3 7 DMA transfers enabling 6 6 fans documentation required for installation 2 7 center wall 3 20 drivers additional information D 9 disconnecting 3 20 DVD ROM diskette drive fastening cable tray to the server 4 8 troubleshooting D 10 fax retrieval service 4 18 DVD ROM diskette drive as...

Страница 132: ...formation 2 1 Remote Insight Lights Out Edition II Installation and User Guide 4 10 I identifying guiding groove 3 11 front holes for rack rail installation 4 3 system board components 3 6 H Important Safety Information 2 1 hard drive power cable connecting 3 15 3 26 3 27 Important Safety Information document ix Important Warranty Information card 1 1 hard drive trays input requirements F 1 instal...

Страница 133: ...ormation window 6 4 latches exiting 6 6 locking location 3 2 features 6 3 locking pressing 3 2 Help window 6 5 rail release See rail release latches levels supported 6 2 LEDs menu options 6 4 CD ROM diskette drive E 3 overview 6 3 drive activity E 3 Physical Drive Information window 6 4 DVD ROM diskette drive E 3 RAID terminology 6 1 front panel E 1 using 6 3 front unit identification 3 3 E 2 Inte...

Страница 134: ...ice 4 18 measuring with the template 4 2 memory 3 7 memory See DIMMs ordering service 4 18 installation guidelines 3 7 installation procedure 3 8 P mirroring RAID configurations 6 2 modifications FCC compliance statement A 3 panels blanking 2 3 password protection how to setup E 10 monitor troubleshooting D 5 PCI riser board assembly mouse connector location 3 6 connector 4 9 installing 3 12 conne...

Страница 135: ... E 7 installing 4 4 power down 3 3 rack template measuring with 4 2 power up 4 15 RAID redundant array of independent drives See also Integrated ATA RAID Configuration Utility power strips grounding requirements 2 5 load restriction 2 5 defined 6 1 power supplies disk mirroring 6 2 load balancing 2 4 disk striping 6 2 output power F 2 drive connection tips 6 9 power switch See Power On Off switch ...

Страница 136: ... identification number A 1 redundant support 5 1 system firmware update 5 8 related documents xii upgrading 5 8 Remote Insight Lights Out Edition II ROM Based Setup Utility See RBSU connector location 3 7 ROMPaq connectors external locations 4 9 disaster recovery 5 2 Installation and User Guide 4 10 interruption 5 3 LAN access 4 12 overview 5 3 remote server features 5 6 routine maintenance 4 18 r...

Страница 137: ...orted operating systems D 9 powering up 4 15 Survey Utility 5 6 preconfigured operating system 4 17 switches registration 4 18 Power On Off 3 3 4 15 E 3 E 7 security features 1 2 settings system configuration switch SW1 E 8 troubleshooting D 2 utilities 5 1 system configuration switch SW1 3 6 E 8 warnings 2 6 Server Profile Diskette registration 4 18 unit identification E 7 server rails fixed symb...

Страница 138: ...on 2 7 center wall 3 21 USB connectors 3 6 4 10 front panel 3 5 4 1 4 7 utilities hard drive trays 3 23 ASR 5 7 PCI riser board assembly 3 9 Insight Manager 5 6 TMRA See temperature maximum recommended ambient overview 5 1 POST 5 7 toe straps B 2 RBSU 5 1 tools See also utilities redundant ROM support 5 1 conductive B 2 ROMPaq 5 3 overview 1 1 5 1 security 1 2 rack model server installation 2 7 se...

Страница 139: ...6 D 7 operating systems supported D 9 equipment damage 4 17 service and support upgrades D 13 hazardous energy circuits D 2 Survey Utility 5 6 hot surfaces 3 2 warranty D 13 plugging telephone connectors into NICs 4 8 wet bulb temperature server F 2 wrist strap B 2 rack installation 2 5 write cache caution 6 6 rack stability xi rack weight 2 6 HP ProLiant DL320 Generation 2 Server Setup and Instal...

Отзывы: