1.
Enter the following command (as root) to update the firmware:
fio-update-iodrive /usr/share/fusionio/images/iodrive_xxxxx.fff
nl
(where xxxxx is the version of the firmware release)
Upgrading the firmware will take several minutes.
NOTE:
The utility detects if the driver is loaded and will not install the firmware. You will get the
error “Driver is not in a valid state to have firmware uploaded.” If this happens, unmount
the drive, run the following command to unload the driver, and then attempt the update
again:
rmmod fio-driver
2.
When the update is complete, enter the following command to shut down the server:
shutdown -h now
IMPORTANT:
For the firmware upgrade to write to the device properly, you must shut the system all the
way down and bring it all the way back up, not just perform a restart.
The following image is an example of the screen display during a firmware update.
# fio-update-iodrive /usr/share/fusionio/images/iodrive_17350.fff
Device ID 0 (48:00.0) Updating device firmware from 15950 to 17350
WARNING: DO NOT TURN OFF POWER WHILE THE FIRMWARE UPDATE IS IN PROGRESS.
Please wait (this may take a while)
Progress
-------------------------
/ 0: 13%
Upgrading the driver
Uninstalling the software
IMPORTANT:
To upgrade the driver, you must uninstall the existing driver and install the new version.
1.
Log into the system as root or use the
su
command to gain root access.
IO Accelerator for BladeSystem c-Class user guide
19