This cable is a three-wire null modem cable. Transmitted data on one end of the cable is connected
to Received data at the other end, and vice versa. The male DB-25 end can be plugged directly
into most serial terminals and printers without any adapters. The female DB-25 end plugs directly
into any RoHS DB-25 serial port.
DB-25 4-Wire Hardware Handshaking (DTR) Cable
The four-wire cable is sufficient for an older terminal, printer, or other DTE (Data Terminal
Equipment) devices configured for DTR (hardware) flow control. However, some terminals and
printers may use a signal other than DTR (Data Terminal Ready) for flow control. In addition,
some terminals and printers may have other cable requirements. Consult your terminal or printer
manual for this information. For more universal compatibility, use a fully-wired DB-25
terminal/printer cable.
lists the pin-out connection between the DB-25 adapter and the DB-25 terminal/printer
with DTR handshaking.
Table B-3 Terminal/Printer Cable with DTR Handshaking
DB-25 Male (Peripheral)
DB-25 Female (Card End)
Signal
Pin
Pin
Signal
RxD
3
Connected to
2
TxD
TxD
2
Connected to
3
RxD
DTR
20
Connected to
5
CTS
SG
7
Connected to
7
SG
GND
Shell
Connected (via
shield) to
Shell
GND
RTS+CTS
4+5
Jumpered
IMPORTANT:
Some terminal or printer manufacturers may use different methods of flow
control. Consult your documentation for specific wiring requirements.
DB-25 Hardware Handshaking (RTS/CTS) Cable
The cabling shown in
is often sufficient for a terminal, printer, or other DTE devices
configured for RTS/CTS (hardware) flow control. However, some terminals and printers may
have other cable requirements. Consult your terminal or printer manual for this information.
For universal compatibility, use a fully-wired DB-25 terminal/printer cable.
lists the pin-out connection between the DB25 adapter and the DB-25 terminal/printer
with RTS/CTS handshaking.
Table B-4 Terminal/Printer Cable with RTS/CTS Handshaking
DB-25 Male (Peripheral)
DB-25 Female (Card End)
Signal
Pin
Pin
Signal
RxD
3
Connected to
2
TxD
TxD
2
Connected to
3
RxD
CTS
5
Connected to
4
RTS
RTS
4
Connected to
5
CTS
DTR
20
Connected to
6+8
DSR+DCD
SG
7
Connected to
7
SG
34
Peripheral Connections