Figure 1-20
Front view of the FIP-200
(1) Slot 1
(2) Slot 2
(3) Combo interface 0
(4) Combo interface 1
(5) OPEN BOOK sign
"OPEN BOOK" sign – Refer to related sections when performing the following operations:
Operation
Reference
Plug/unplug a FIP-200
“Installing and Removing a FIP” in Chapter 4 “Installing the Router”
Plug/unplug an interface module
"Installing and Removing a HIM" and “Installing and Removing a
MIM” in Chapter 4 “Installing the Router”
Connect an Ethernet cable
“Connecting the Management Ethernet Interface” and “Connecting
Ethernet Cables” in Chapter 4 “Installing the Router”
Plug/unplug an optical fiber
“Connecting an optical Ethernet interface" in Chapter 4 “Installing
the Router”
Technical specifications
Table 1-23
Technical specifications for the FIP-200
Item
Specifications
Processor
MIPS 1 GHz
Processor cores
8
Flash
4 MB
Memory type and size
DDR2 SDRAM
1 GB (default, two 512 MB memory modules)
2 GB (maximum, 1.5 GB not supported)
Memory modules must be used in pairs. Make sure they are of the same type
and size.
NVRAM
128 KB
Combo interfaces
2
2 electrical interfaces
(automatic MDI/MDI-X)
10 Mbps, half/full-duplex
100 Mbps, half/full-duplex
1000 Mbps, full-duplex
2 optical interfaces
1000 Mbps, full-duplex
HIMs
2
MIMs
2
Dimensions (H × W × D)
45 × 399 × 412 mm (1.77 × 15.71 × 16.22 in.)
Hardware encryption
Supported