51
Figure 45
Pull out the power supply
6.
Install a new power supply. For how to install a power supply, see the chapter “
Installing the
firewall
.”
Replacing an MPU
CAUTION:
The MPU does not support hot swapping. Before replacing an MPU, you must switch off the power supply
of the firewall.
Follow these steps to replace a MPU:
1.
Switch off the power supply.
2.
Use a Philips screwdriver to loosen the captive screws of the MPU to be removed until all spring
pressure is released.
3.
Holding the ejector levers of the MPU with both hands, pull the ejector levers outward, and gently
pull the MPU out of the slot along the slide rails.
Figure 46
Pull the MPU out of the slot
4.
Install a new MPU. For how to install an MPU, see the chapter “
Installing the firewall
.”