Installing the System
Installing Additional Components
Chapter 3
88
Figure 3-31 Inserting DIMM into Connector
Step 6.
Replace the memory airflow guide. (See “Replacing the Memory Airflow Guide” on page 80.)
Step 7.
Replace the server cover. (See “Removing and Replacing the Top Cover on a Rack-Mounted Server”
on page 64.)
Step 8.
Reconnect all power and external cables and turn on the server.
Step 9.
Verify the memory installation by using the system utilities.
•
Use the iLO MP commands to verify operation.
•
Use the BCH commands to verify operation.
•
Use diagnostics provided by the offline diagnostic environment (ODE) to exercise the memory
added.
Removing and Replacing the PCI Card Cage
Accessory cards are installed in a removable PCI card cage. This section explains how to remove and replace
the PCI card cage. Removal is required to install accessory cards.
Removing the PCI Card Cage
To remove the PCI card cage from the server, follow these steps:
Step 1.
Remove the cover. (See “Removing and Replacing the Top Cover on a Rack-Mounted Server” on
page 64.)
Step 2.
Disconnect the cables from the PCI cards.
Содержание 9000 rp3410
Страница 8: ...Contents 8 ...
Страница 57: ...Installing the System Introduction Chapter 3 57 Figure 3 4 HP 9000 rp3410 rp3440 Server Pedestal Mount ...
Страница 100: ...Installing the System Installing Additional Components Chapter 3 100 Figure 3 45 Connecting the Power Pod Cable ...
Страница 128: ...Installing the System Troubleshooting Chapter 3 128 ...
Страница 130: ...Installing the System Troubleshooting Chapter 3 130 ...
Страница 146: ...Chapter 5 Troubleshooting Cleaning Procedures 146 ...
Страница 240: ...Appendix A Replacement Parts Replaceable Parts List 240 ...
Страница 248: ...Appendix B Utilities iLO MP 248 ...
Страница 250: ...Physical and Environmental Specifications Appendix C 250 ...