Analyzing
Measurement
Results
Manual
Analysis
T
o
Draw
Line
through
Specied
P
oint
with
Specied
Gradient
1.
Select
NNNNNNNNNNNNNN
LINE
primary
softkey
.
2.
Set
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
LINE
SELECT
softkey
to
1
or
2 .
Selecting
this
softkey
toggles
the
setting.
3.
Set
NNNNNNNNNNNNNN
LINE
secondary
softkey
to
ON .
A
line
and
two
cursors
are
displayed.
Selecting
NNNNNNNNNNNNNN
LINE
secondary
softkey
toggles
as
follows:
OFF
!
ON
!
OFF
4.
Select
NNNNNNNNNNNNNNNNNNNNNNNNNNNNN
GRAD
MODE
secondary
softkey
if
it
is
not
highlighted.
Softkey
becomes
highlighted.
One
cursor
disappears
(if
there
are
two
cursors
in
the
plotting
area
before
this
step).
Selecting
N
NNNNNNNNNNNNNNNNNNNNNNNNNNNN
GRAD
MODE
secondary
softkey
toggles
between
highlighted
and
not
highlighted.
5.
Move
the
cursor
to
desired
location
by
using
arrow
keys
of
the
MARKER/CURSOR
key
group
.
6.
Select
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
GRAD
VALUE
secondary
softkey
,
then
enter
gradient
value
.
The
line
goes
through
the
cursor
with
specied
gradient.
When
lines
are
displayed
and
when
ON
is
set
in
the
LINE
P
ARAMETER
eld
on
the
DISPLA
Y
:
DISPLA
Y
SETUP
page
,
the
X
and
Y
intercepts
and
gradients
of
selected
line
are
also
displayed
in
the
plotting
area.
T
o
turn
o
the
line
intercept
and
gradient
display.
Select
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
DISPLAY
SETUP
primary
softkey
,
then
set
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
LINE
PRMTRS
secondary
softkey
to
OFF .
T
o
turn
o
the
data
variable
display
area.
Use
the
following
procedure:
1.
Select
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
DISPLAY
SETUP
primary
softkey
.
2.
Set
NNNNNNNNNNNNNNNNNNNNNNNNNN
DATA
VAR
secondary
softkey
to
OFF .
T
o
move
the
selected
cursor
to
the
selected
marker
position.
Select
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
CURSOR
TO
MARKER
secondary
softkey
.
4-15
Содержание 4155A
Страница 2: ...Semiconductor Parameter Analyzer User s Task Guide ...
Страница 6: ......
Страница 7: ......
Страница 8: ......
Страница 9: ......
Страница 19: ...Contents ...
Страница 20: ...1 Introducing the HP 4155A 4156A ...
Страница 47: ...Introducing the HP 4155A 4156A An Overview of Functions ...
Страница 48: ...2 Installation ...
Страница 84: ...Installation Installing Accessories Attaching HP 16441A R Box to Shielding Box 2 37 ...
Страница 94: ...3 Making a Measurement ...
Страница 122: ...Making a Measurement Sweep Measurements Example The following gure shows an example setup to de ne Hfe 3 29 ...
Страница 143: ...Making a Measurement Sampling Measurements Example The following example shows the constant output conditions 3 50 ...
Страница 158: ...Making a Measurement Stress Force Example The following gure shows an example of STRESS STRESS FORCE page 3 65 ...
Страница 161: ...Making a Measurement Stress Force ...
Страница 162: ...4 Analyzing Measurement Results ...
Страница 170: ...Analyzing Measurement Results Manual Analysis Example The following gure shows an example to display a short cursor 4 9 ...
Страница 192: ...Analyzing Measurement Results Manual Analysis Example The following gure shows an example to display marker 4 31 ...
Страница 206: ...5 Filer ...
Страница 211: ...Filer File Operations Example The following gure shows example that displays le catalog 5 6 ...
Страница 230: ...Filer File Operations Example The following gure shows an example that initializes a diskette with DOS format 5 25 ...
Страница 232: ...Filer File Operations Example The following gure shows an example that backs up a diskette 5 27 ...
Страница 233: ...Filer File Operations ...
Страница 234: ...6 If Y ou Have A Problem ...
Страница 276: ...7 Manual Changes Depending on ROM Version ...
Страница 279: ...Manual Changes Depending on ROM Version Change 1 ...