Analyzing
Measurement
Results
Manual
Analysis
T
o
Specify
between
Measurement
P
oints
on
Curve
1.
Select
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
MARKER/CURSOR
primary
softkey
.
2.
Set
NNNNNNNNNNNNNNNNNNNN
MARKER
secondary
softkey
to
ON .
Marker
and
marker
coordinates
are
displayed.
Selecting
NNNNNNNNNNNNNNNNNNNN
MARKER
toggles
between
ON
and
OFF .
3.
(if
both
Y1
and
Y2
axis
are
set
up)
Select
the
desired
marker
(axis)
by
using
NNNNNNNNNNNNNN
AXIS
primary
softkey
.
The
selected
marker
is
highlighted.
Selecting
NNNNNNNNNNNNNN
AXIS
primary
softkey
toggles
between
Y1
and
Y2 .
4.
Set
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
INTERPOLATE
secondary
softkey
to
ON .
Selecting
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
INTERPOLATE
secondary
softkey
toggles
between
ON
and
OFF .
5.
Rotate
rotary
knob
to
move
the
marker
to
desired
measurement
point.
If
both
Y1
and
Y2
axis
are
set
up
,
a
circle
marker
( )
is
displayed
on
measurement
curve
of
Y1
axis
,
and
an
asterisk
marker
(3 )
is
displayed
on
measurement
curve
of
Y2
axis
.
The
MARKER
coordinate
elds
indicate
the
location
of
markers
.
The
rst,
second,
and
third
elds
are
X,
Y1,
and
Y2
coordinates
,
respectively
.
X
and
Y1
indicate
location
of
marker
on
Y1
curve
.
X
and
Y2
indicate
location
of
marker
on
Y2
curve
.
T
o
turn
o
markers.
Set
the
NNNNNNNNNNNNNNNNNNNN
MARKER
secondary
softkey
to
OFF .
T
o
move
marker
to
maximum
or
minimum
value
of
measurement
curve.
Select
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
MARKER
MIN/MAX
secondary
softkey
.
The
marker
searches
for
minimum
or
maximum
value
in
measurement
order
from
the
present
location
every
time
you
select
the
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
MARKER
MIN/MAX
secondary
softkey
.
T
o
move
marker
to
next
V
AR2
step
or
append
curve.
Select
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
MARKER
SKIP
secondary
softkey
.
Marker
moves
to
next
V
AR2
step
curve
or
next
append
curve
every
time
you
select
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
MARKER
SKIP
.
4-6
Содержание 4155A
Страница 2: ...Semiconductor Parameter Analyzer User s Task Guide ...
Страница 6: ......
Страница 7: ......
Страница 8: ......
Страница 9: ......
Страница 19: ...Contents ...
Страница 20: ...1 Introducing the HP 4155A 4156A ...
Страница 47: ...Introducing the HP 4155A 4156A An Overview of Functions ...
Страница 48: ...2 Installation ...
Страница 84: ...Installation Installing Accessories Attaching HP 16441A R Box to Shielding Box 2 37 ...
Страница 94: ...3 Making a Measurement ...
Страница 122: ...Making a Measurement Sweep Measurements Example The following gure shows an example setup to de ne Hfe 3 29 ...
Страница 143: ...Making a Measurement Sampling Measurements Example The following example shows the constant output conditions 3 50 ...
Страница 158: ...Making a Measurement Stress Force Example The following gure shows an example of STRESS STRESS FORCE page 3 65 ...
Страница 161: ...Making a Measurement Stress Force ...
Страница 162: ...4 Analyzing Measurement Results ...
Страница 170: ...Analyzing Measurement Results Manual Analysis Example The following gure shows an example to display a short cursor 4 9 ...
Страница 192: ...Analyzing Measurement Results Manual Analysis Example The following gure shows an example to display marker 4 31 ...
Страница 206: ...5 Filer ...
Страница 211: ...Filer File Operations Example The following gure shows example that displays le catalog 5 6 ...
Страница 230: ...Filer File Operations Example The following gure shows an example that initializes a diskette with DOS format 5 25 ...
Страница 232: ...Filer File Operations Example The following gure shows an example that backs up a diskette 5 27 ...
Страница 233: ...Filer File Operations ...
Страница 234: ...6 If Y ou Have A Problem ...
Страница 276: ...7 Manual Changes Depending on ROM Version ...
Страница 279: ...Manual Changes Depending on ROM Version Change 1 ...