Frequency Sweep
In the frequency sweep mode, the function generator “steps” from the
start frequency
to the
stop frequency
at a
sweep rate
which you specify.
You can sweep up or down in frequency, and with either linear or
logarithmic spacing. You can also configure the function generator to
output a single sweep (one pass from start frequency to stop frequency)
by applying an external trigger.
The function generator can produce a
frequency sweep for sine, square, triangle, ramp, or arbitrary waveforms.
For more information on the fundamentals of frequency sweeps, refer to
chapter 7, “Tutorial”.
To Select Sweep Modulation
•
The
Swp
annunciator turns on when the sweep mode is enabled.
•
Only one modulation mode can be enabled at a time. When you
enable the sweep mode, the previous modulation mode is turned off.
•
Front-Panel Operation
: Enable the sweep mode
before
you set up the
other sweep parameters. Press
Shift Sweep
to output a sweep using
the present settings for amplitude and offset voltage.
•
Remote Interface Operation
: To ensure proper operation, you should
enable the sweep mode
after
you have set up the other modulation
parameters.
SWEep:STATe {OFF|ON}