Sweep Trigger Source
In the
triggered sweep
mode, the function generator outputs a single
sweep each time a trigger is received. After one sweep from the start
frequency to the stop frequency, the function generator waits for the
next trigger while outputting the start frequency.
•
Sweep trigger source:
Internal
, Single, or External.
The default
is Internal.
•
When the
internal
trigger source is enabled (default), the function
generator outputs a continuous sweep at a rate determined by the
sweep rate
specified.
•
Pressing
Single
to enable the
single
trigger mode also enables the
external
trigger mode. External triggering is like the front-panel
single trigger mode except that you apply a trigger signal to the
rear-panel
Ext Trig
terminal. The function generator is triggered on
the
rising edge
of a
TTL
pulse.
•
The
Trig
annunciator turns on when the function generator is waiting
for a single or external trigger.
•
Front-Panel Operation
: Pressing
Single
to enable the single
trigger mode also enables the external trigger mode.
Press
Shift Internal
to enable the internal trigger mode.
•
Remote Interface Operation
:
TRIGger:SOURce {IMMediate|EXTernal|BUS}
See “Triggering” on page 98 for more information.
3
Chapter 3 Features and Functions
Frequency Sweep
97
Содержание 33120A
Страница 6: ...1 Quick Start 1 ...
Страница 20: ...2 Front Panel Menu Operation 2 ...
Страница 44: ...3 Features and Functions 3 ...
Страница 115: ...8 Specifications 8 ...