6
4 214 283 / 00
ASSEMBLY
Boiler door opens to the left
The boiler door hinges can be changed over to enable
the door to open to the left side. This can be useful where
space is limited.
The hinges are changed over as follows:
1. Tighten the top and bottom locknuts (1, Fig. 01) to-
2.
opening side, i.e.,
-
nuts and
-
nuts.
3. Unscrew locknut (3) and turn back approx. 1 cm.
4. Mount the burner plug connector on the other side.
The cable must not contact any hot parts.
Boiler door hinges must be changed over only by
Hoval Service!
Figure shows situation as delivered
(boiler door opens to the right)
1
2
3
3
1
2
Fig. 01