230 VOlT CONVERSION 
INSTRUCTIONS

Hot spring spas must be wired in accordance with all applicable local 
electrical codes. All electrical work should be done by an experienced, 
licensed electrician. We recommend the use of appropriate electrical 
conduit, fittings, and wire for all circuits.

Refer to the following instructions to convert from 115 volt to 230 volt

ImporTanT:

 converting the spa to 230 volt operation will require both 

an authorized Hot Spring service agent and a qualified electrician.

Required Part: A Subpanel (230 volt convertable) available from your 
Hot Spring dealer.

1. disconnect the power cord from the house receptacle.

2. open the equipment compartment door.

3. Remove the screws on the front of the spa control box.

4. open the control box cover.

5. Identify Terminal block 

located in the lower 
left-hand corner inside 
the control box.

6. Refer to illustration, 

Step 1. Remove the 2 
pin jumper attached to 
terminals 
4 and 5.

7. Refer to illustration, 

Step 1. Remove the 
wire jumper from 
terminals 2, and 6. 

8. Refer to illustration, 

Step 2. Remove the 
power cord wires from 
5, 7 and gRd (not 
illustrated).

9. unscrew the power 

cord strain relief and 
remove the power cord from the access hole in the control box.

WarnInG:

 do not allow pliers to contact any electronic components 

inside the control box.

converting from 115 volts to 230 volts changes the voltage supplied 
to the heater from 115-volts to 230 volts. The jet pump will continue to 
operate at 115 volts.

Have your licensed electrician wire subpanel from a 50A Main Service, 
then from subpanel into the spa's control box using the following illustration 
or use the wire diagram on the inside of the control box lid.

ImporTanT:

 

The subpanel must be placed in sight of the spa, at a 

minimum distance of 5 feet away.

Page 31

Remove the Terminal Block Power Jumper 
using needlenose pliers From terminal 4-5. 
Remove wire jumper from 2 & 6.

Remove the three power cord wires from 

terminal block 5,7 and gRd. leave Terminal 

Block Power Jumper 6-7 in place.

Step 1

Step 2

INSTAllATIoN 
INSTRucTIoNS

All 115 volt Hot Spring

®

 spa 

models come equipped with 
approximately 15 feet of 
useable power cord (this is 
the maximum length allowed 
by underwriters laboratory 
and the National electric 
code). When the spa is 
installed, the power cord will 
come out of the bottom of 
the equipment compartment 
door. For your safety, when 
the electrician is installing 
the 20 amp single electrical 
outlet and waterproof cover,  
the outlet should be no closer 
than 5 feet (1.5 meters) and 
no farther than 10 feet from 
the spa [reference National 
electrical code 680-6a(1) and 680-41a].

The ground Fault circuit Interrupter (gFcI) is located at the end of 
the power cord. This device is for your protection. It is very important 
to protect it from rain and other moisture. Test once a month, with the 
plug connected to the power supply,

1. Push the “TeST” button on the gFcI breaker. The spa should stop 

operating and the gFcI power indicator will go out. 

2. Wait 30 seconds, then push the “ReSeT” button. Power will be 

restored to the spa and the gFcI power indicator will turn on.

If the gFcI fails to operate in this manner, your spa may have an 
electrical malfunction, and you may be risking electrical shock. Turn off 
all circuits and do not use the spa until the problem has been corrected 
by an authorized service agent.

WarnInG:

 Removal of the gFcI from the spa’s power cord will 

result in an unsafe spa and will void the spa’s warranty.

IMPoRTANT: Should you ever find the need to move or relocate your 
Hot Spring ® spa, it is essential that you understand and apply these 
installation requirements. your Hot Spring spa has been carefully 
engineered to provide maximum safety against electric shock. 
Remember, connecting the spa to an improperly wired circuit will 
negate many of its safety features.

AdVANTAge To HAVINg  
youR SPA coNVeRTed

• 

In the 115 volt configuration, either the heater, or the jet pump can 
operate, but they can’t work at the same time. In a 115 volt system, 
as long as the jet pump is activated, the heater will not turn on. on 
the other hand, when the spa is converted to operate in the 230 volt 
configuration, the heater and jet pump can operate simultaneously.

• 

The heater will operate at 1500 watts when the spa is configured as 
a 115 volt cord-and-plug connected model, and at 6000 watts when 
the spa is configured as a 230 volt converted model heating your spa 
water faster.

electrical Requirements

Содержание ARIA AR

Страница 1: ...H i g h l i f e C o l l e c t i o n...

Страница 2: ...ing Corporation reserves the right to change specifications or design without notification and without incurring any obligation Important In most cities and counties permits will be required for the i...

Страница 3: ...ModelAR Jet System Menu 20 Vanguard Model VV Jet System Menu 21 Sovereign Model II Jet System Menu 22 PRODIGY Model H Jet System Menu 23 jETSETTER Model JJ Jet System Menu 24 Spa Care and Maintenance...

Страница 4: ...or other metal within 5 feet 1 5 m of the spa to comply with local requirements The means of disconnection must be readily accessible but must be installed at least 5 feet 1 5 m from the spa Your spa...

Страница 5: ...han the flow rate marked on the original suction fitting There is a danger of slipping and falling Remember that wet surfaces can be very slippery Take care when entering or exiting the spa Never oper...

Страница 6: ...act your Hot Spring dealer and request Part 70798 Safety Information Save these instructions Important spa instructions The following contains important spa information and we strongly encourage you t...

Страница 7: ...am jet has a strong flow of water and air which quickly soothes away tension 11 The Precision jet delivers a therapeutic massage 12 The Moto Massage DX is a moving jet It has two warm streams of water...

Страница 8: ...decrease the jet pressure Hydrostream Jet The Hydrostream jet is a mid size hydromassage jet that delivers a great massage to the feet back and shoulder areas Turn the faceplate clockwise to increase...

Страница 9: ...pa water Press the soft button next to CLEAN on the home screen to circulate the spa water for a ten minute period 6 During the super chlorination period rotate the SmartJet lever s through both opera...

Страница 10: ...s observe the following guidelines Allow only a responsible person to handle spa chemicals Keep them out of the reach of children Accurately measure the exact quantities specified never more Do not ov...

Страница 11: ...and physical discomfort for spa users A low pH dissipates sanitizer causes corrosion and irritates spa users A high pH level will neutralize sanitizer promote scaling and cloud water The recommended p...

Страница 12: ...ptional The ACE Salt Water Sanitizing System converts water and sodium chloride salt into chlorine sanitizer The Ace is compatible with chlorine based systems and chemicals Although the system is redu...

Страница 13: ...n theACE Owner s Manual Long time Periods 5 14 Days Prior to leaving 1 At least one day before you leave set the temperature to its lowest level This setting should represent an approximate water temp...

Страница 14: ...nopersulfate is the non chlorine oxidizer used with the FreshWaterAg silver ion purification system Not a sanitizer Nitric Acid The formulation of nitric acid a highly corrosive chemical is a byproduc...

Страница 15: ...will go back to the Home screen where the screen will remain on for several minutes before going to the sleep mode Pressing any button will wake up a sleeping display Indicator Lights At a glance the...

Страница 16: ...button next to Temp Lock Off to change the screen to Temp Lock On IMPORTANT The red Temperature Spa lock icon will be lit during a temperature lock condition To deactivate the Temperature Lock Press...

Страница 17: ...on off Spa Lock When activated the Spa Lock feature disables all functions on the main and auxiliary control panels It prevents others from tampering with the jets lights and temperature settings on y...

Страница 18: ...o change languages Press the OptionS hard button on the Main Control panel Press the soft button next to Set Up Press the soft button next to Language until the desired language is visible IMPORTANT S...

Страница 19: ...et pump 2 on High 4th press jet pumps OFF sovereign pRODIGY 1st press jet pump on High 2nd press jet pump OFF Operating Instructions Light Control The Light buttons on the Auxiliary control panel will...

Страница 20: ...Precision jets c 4 directional Precision jets d 1 Moto Massage DX jet e 2 JetStream jets Jet Pump 2 Jet System 1 Right SmartJet lever in position a 6 HydroStream jets b 1 Water Feature c 4 HydroStream...

Страница 21: ...et c 2 directional Precision jets d 1 Moto Massage DX jet e 4 directional Precision jets above Moto Massage jet f 2 directional Precision jets Jet Pump 2 Jet System 2 Right SmartJet lever in position...

Страница 22: ...s d 1 Moto Massage DX jet e 1 JetStream jet Jet Pump 2 Jet System 1 Right SmartJet lever in position a 7 directional Precision jets b 4 HydroStream jets c 3 Jet Cluster system on back wall 2 dual port...

Страница 23: ...position a 2 dual port rotary jets b 4 Precision jets above Moto Massage DX c 1 Water Feature d 2 Directional hydromassage e 2 Soothing Seven jets Jet Pump 2 Jet System 2 SmartJet lever in position a...

Страница 24: ...n a 3 Jet Cluster system 2 dual port rotary 1 directional hydromassage b 2 JetStream jets Jet Pump 1 Jet System 1 1 1 Moto Massage jet 2 4 directional Precision jets above Moto Massagejet 3 2 directio...

Страница 25: ...t Cluster system 2 dual port rotary 1 directional hydromassage e 1 directional Precision jet Jet System 2 SmartJet lever in position a 1 Moto Massage DX jet b 1 directional hydromassage jet c 10 direc...

Страница 26: ...ectional hydromassage jet on left wall 2 Soothing Seven jets on front left Jet System 2 SmartJet lever in position 1 JetStream jet on rear wall 3 Jet Cluster system on left rear 2 dual port rotary 1 d...

Страница 27: ...et Cluster system on front right 2 dual port rotary jets 1 directional hydromassage jet Jet System 1 SmartJet lever in position 1 Moto Massage DX jet on left rear 4 directional Precision jets above Mo...

Страница 28: ...also achieve the same results if that is an option for you PREVENTION OF FREEZING Your spa has been designed and engineered for year round use in any climate In some areas extremely cold temperatures...

Страница 29: ...er of occupants all contribute to determining the appropriate time between filter cleanings More use means that more frequent filter cleanings are required Failure to maintain the cartridges in a clea...

Страница 30: ...and recommended stains SPASTONE cabinet To clean your SpaStone cabinet or steps use a mild household detergent and soft cloth or sponge and wipe gently Do not rub the SpaStone step or cabinet nor use...

Страница 31: ...the cover just above the skirt Gently push do not lift with both hands towards the opposite rear corner of the cover diagonally As the cover opens the gas springs will allow the cover to come to a gen...

Страница 32: ...utral wire is connected to the load neutral of the 20 amp breaker MAIN SERVICE ELECTRICAL PANEL 230V 50 Amp 2 POLE CIRCUIT BREAKER NON GFCI 1 2 H1 3 4 5 FACTORY WIRED HEATER L2 10 AWG RED L1 10 AWG BL...

Страница 33: ...d to the load neutral of the 30 amp breaker MAIN SERVICE ELECTRICAL PANEL 230V 50 Amp 2 POLE CIRCUIT BREAKER NON GFCI 1 2 H1 3 4 5 FACTORY WIRED HEATER L2 12 AWG RED L1 12 AWG BLUE L2 10 AWG RED L1 10...

Страница 34: ...15 feet of useable power cord this is the maximum length allowed by Underwriters Laboratory and the National Electric Code When the spa is installed the power cord will come out of the bottom of the...

Страница 35: ...pa has been filled with water turn it on and test all the circuit breakers Each breaker should be tested prior to each use Here s how 1 Push the Test button on each GFCI breaker and observe it click o...

Страница 36: ...itions that would normally invalidate the limited warranty such as water chemistry damage do not apply to the No Fault heater It is important to note that the No Fault heater is protected by both the...

Страница 37: ...surface no spa surface material can withstand this kind of abuse damage to components or spa surface caused by improper water chemistry maintenance and damage to the spa surface caused by leaving the...

Страница 38: ...ty seconds to reset heater high limit If it will not reset check for clogged filters If tripping continues call for service Green Logo Ready indicator blinking Temperature sensor problem Disconnect po...

Страница 39: ...50 square feet 6 000 400 gallons 1 514 liters 789 lbs 358 kg 5 175 lbs 2 347 kg 135 lbs per sq foot 230 volt 50 amp Single phase GFCI protected circuit Sovereign Model II Seats 6 Adults 6 8 x 7 9 2 03...

Страница 40: ...be free from defects in materials and workmanship for two years Year FreshWater III Ozone Warranty Watkins warrants the electrical components ozone tubing check valve injector corona discharge cell an...

Страница 41: ......

Страница 42: ......

Страница 43: ......

Страница 44: ...rporation Hot Spring Moto Massage Vista Grandee Envoy Vanguard Sovereign Aria Prodigy Jetsetter Jet Cluster SmartJet Comfort Control No Fault IQ 2020 Wavemaster Silent Flo 5000 Soothing Seven Soothing...

Отзывы: