Copyright 2013 HotSpot Energy 

SAFETY PRECAUTIONS

 

  

Please read this installation manual completely before installing the product. If the power cable is damaged, replacement 
work shall be performed by authorized personnel only. Installation must be performed in accordance with the NEC and CEC by 
authorized personnel only. All the pictures in the instructions are for explanation purposes only. The actual shape may vary. 
Contact an authorized service technician for repair, maintenance or installation of this unit. This appliance is not intended for 
use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, 
unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their 
safety. Children should be supervised to ensure that they do not play with the appliance. The design and specifications are 
subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. 

WARNING

 

 

 

 Strictly adhere to the instructions in this manual.  If the installation manual is not followed, it may cause water leakage, 
electrical shock, fire, death. Use the attached accessories parts and specified parts for the installation, otherwise, it will 
cause the unit to fail, water leakage, electrical shock, and possibly fire. Install at a suitable and firm location which is able 
to withstand the units weight. If the unit is mounted on an approved bracket, unit may drop and cause injury. For 
electrical work, follow all local and national wiring codes and these installation instructions. Use the proper size and type 
of cable and connect it tightly, clamp the cable so that no external force will be present on the terminal. If the connection 
or fitting is not tight, it may heat-up or could cause a fire at the connection. Wire routing must be properly arranged so 
that control board cover is properly fitted. If control board cover is not fitted perfectly, it may cause  the connection to 
heat up and could cause a fire or electrical shock. When installing the line set, take care not to let moisture or foreign 
substances other than the specified refrigerant go into refrigeration cycle. Otherwise, it will cause lower capacity, 
abnormal high pressure in the refrigeration cycle, possible explosion and injury. 

This equipment must be grounded and installed according to the NEC. It may cause electrical shock or damage to the 
system if not grounded properly. 
 
Do not install the unit in a location where leakage of flammable gas may occur. If flammable gas leaks and 
accumulates near the unit, it may cause a fire or explosion. 
 
This unit produces condensate. Install the drain piping as mentioned in the installation instructions. If drainage is not 
correct, water may enter the room and cause damage. 
 

This unit uses high voltage DC power. There are multiple capacitors within the unit that may contain dangerous 
power, even after the power supply has been disconnected.  

 
Refer any service to a qualified professional. See the DC4812VRF SERVICE MANUAL for service information.  
 

Capacitors MUST BE DISCHARGED before servicing any electrical components of this system!  
 
Batteries: Ma

ke sure to follow the NEC and instructions provided by the battery manufacturer when wiring, 

connecting, and grounding the battery plant. 
 

Charge Controllers

: Make sure to follow the NEC and instructions provided by the manufacturer. 

 

Solar Array: 

Follow the NEC and manufacturers instructions for mounting, connecting, and grounding solar power 

components. 
 

Содержание DC4812VRF DC

Страница 1: ...DC4812VRF Installation Guide Version 1 4 Copyright 2013 HotSpot Energy 1...

Страница 2: ...any restrictions on the purchase of R410A refrigerants R 410A is not an ozone depleting substance At this time the purchase of R 410A refrigerant is not restricted in the US There is no technician ce...

Страница 3: ...erous power even after the power supply has been disconnected Capacitors MUST BE DISCHARGED before servicing any electrical components of this unit Refer any installation or service to a qualified pro...

Страница 4: ...2 Capacitor Warning 3 Table of Contents 4 Safety Precautions 5 Selecting Installation Location 6 Indoor Unit Installation 7 Connecting Power Cables 10 Outdoor Unit Installation 13 Recharging Empty Uni...

Страница 5: ...it tightly clamp the cable so that no external force will be present on the terminal If the connection or fitting is not tight it may heat up or could cause a fire at the connection Wire routing must...

Страница 6: ...animals or plants near the unit which could be affected by hot air discharged Ensure the clearances indicated by arrows from the wall ceiling fence or other obstacles See figure 2 Do not place any obs...

Страница 7: ...e wall according to the wall structure and corresponding mounting points on the installation plate The installation plate is provided with the machine Dimensions are in mm unless otherwise stated For...

Страница 8: ...cable and drain hose securely with tape evenly as shown in figure 8 on the right Because the condensed water from rear of the indoor unit is gathered in a reservoir and is piped out of room do not pu...

Страница 9: ...installation plate Ensure the hooks are properly seated on the installation plate by moving it in left and right motions 3 Piping can be made by easy by supporting the indoor unit with a cushioning ma...

Страница 10: ...ble materials 8 Refer to the Electrical Connection Diagram located on the panel of the indoor outdoor unit to connect the wires All wiring must comply with local and national electrical codes and be i...

Страница 11: ...wn below AWG Wire Gauge Sizing Guide For DC4812VRF Air Conditioner DC4812VRF Air Conditioner Minimum Wire Gauge Sizing Chart for Connecting Outdoor Power Distance 10 ft 20 ft 30 ft 40 ft 50 ft 75 ft 1...

Страница 12: ...cable clamp Figure 12 Figure 11 If using an installation bracket the installation bracket should be installed according to the installation bracket diagram The installation wall should be solid brick...

Страница 13: ...g mode REFRIGERANT PIPE CONNECTION Flaring 1 Cut a pipe with a pipe cutter 2 Remove flare nuts attached to the indoor and out door units Slide them over the end of the pipes after removing burs from t...

Страница 14: ...cy is tested basing on the pipe length of 7 5 meters Air purging Air and moisture in the refrigerant system have undesirable effects and can damage the system Therefore the indoor unit and tubing betw...

Страница 15: ...entering Operation noise of the vacuum pump changes and a compound meter indicates 0 instead of minus 5 After the evacuation is complete fully close the Lo handle of the manifold valve and stop the op...

Страница 16: ...e gas and liquid side service valves are fully open 1 Connect the power press the ON OFF button on the remote controller to turn the unit on 2 Use the MODE button to select COOL HEAT AUTO and FAN to c...

Страница 17: ...it and tubing between the indoor and outdoor unit must be leak tested and evacuated to remove any non condensables and moisture from the system before charging with R410A Freon Evacuation with vacuum...

Страница 18: ...icates 76cmHg 1x105Pa After the evacuation is complete fully close the LOW valve of the manifold valve and stop the operation of the vacuum pump Disconnect the yellow hose from the vacuum pump and con...

Страница 19: ...long as they are wired for 48 volts HotSpot does not provide batteries Please source your batteries from a reputable supplier and rely only upon the installation and use instructions provided by the b...

Страница 20: ...Copyright 2013 HotSpot Energy 20 Outdoor Electrical Connections...

Страница 21: ...all wiring to and from the battery bank before maintenance or cleaning to reduce the risk of fire shock or explosion Always remove the negative terminal from the battery before servicing Use caution w...

Страница 22: ...cable standards and codes It is very important that the wire you choose is large enough to carry the amount of current from your charge sources batteries and loads or you will experience a substantial...

Страница 23: ...ithout limitation the risk of electric shock One individual module may generate DC voltages greater than 50 volts when exposed to direct sunlight Contact with a DC voltage of 50V or more is extremely...

Страница 24: ...insulated tools that are approved for working on electrical installations Only perform installation in dry conditions Abide with the safety regulations for all other components used in the system incl...

Страница 25: ...structions and the Morningstar instructions follow the Morningstar instructions or call HotSpot technical support with any questions TRISTAR MPPT Solar System Controller Please refer to the instructio...

Страница 26: ...be connected to the TriStar MPPT to start and operate the controller The controller will not operate only from solar input Turn the solar disconnect on If the solar array is in full sunlight the TriS...

Страница 27: ...your mounting hardware from somewhere other than HotSpot Energy consult with your supplier for detailed instructions If HotSpot Energy provided the hardware it will either be from Iron Ridge or DPW P...

Страница 28: ...to the Relay Driver GenStart Supplement for detailed wiring and configuration details The document is available on the Morningstar website at http www morningstarcorp com en support library RD IOM Op...

Отзывы: