Checking the tightness of the connection
!
When the installation process is complete, check the pipe
fittings for leaks using a soapy solution. Never use a flame.
!
Should the gas pressure used be different (or vary slightly)
from the recommended pressure, a suitable pressure
regulator must be fitted to the inlet pipe (in order to comply
with current national regulations).
Electrical
connections
DATA PLATE
see data plate
This appliance conforms to the following
European Economic Community directives:
- 2006/95/EEC dated 12/12/06 (Low
Voltage) and subsequent amendments
- 2004/108/EEC dated 15/12/04
(Electromagnetic Compatibility) and
subsequent amendments
- 93/68/EEC dated 22/07/93 and
subsequent amendments.
- 2009/142/EEC dated 30/11/09 (Gas) and
subsequent amendments.
- 2002/96/EC and subsequent
amendments.
Table 1 Natural Gas Adjusting the burner’s
(G25 / 25 mbar) primary air
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
25
20
30
Fast (R)
Semi Fast (S)
Auxiliary (A)
Supply pressures
Burner
Diameter
(mm)
Thermal Power
kW (p.c.s.*)
157
132
110
3.00
1.90
1.00
Nomin. Reduc.
1.00
0.80
0.50
Nozzle
1/100
Flow*
l/h
(mm)
(G25)
132
103
75
(mm)
3.2
1.5
1.5
332
210
111
Burner and nozzle specifications
*
At 15°C and 1013 mbar-dry gas
Natural G25 P.C.S. = 32.49 MJ/m³
PK 644 D GH X/HA G
PK 644 D GH /HA G
PKQ 644 D GH /HA G
PKQ 755 D GH /HA G
A
S
R
S
A
A
R
S
S