![HOSSEVEN KH.2545 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/hosseven/kh-2545/kh-2545_instruction-manual_2165629005.webp)
IN A EMERGENCY
If there is a fi
re in the flue connection :
a) Close the loading door and the ash tray door
b) Close the comburent air registers
c) Use carbon dioxide ( CO
₂
powder ) extinguishers to put out the fire
d) Request the immediate intervention of the Fire Brigade
With thermal insulation in accordance with the regulations regarding energy saving, the heated volume is greater. With temporary
heating, in the event of interruptions which last more than 8 hours, the heating capacity is reduced by about 25%.
The declared technical data have been achieved by burning beech wood class
“A1”
according to the requirement UNI EN ISO 17225-
5 and wood moisture content less than 20%. By burning a different kind of wood the effciency of the product itself could change and
some specifc adjustments on the appliance could be needed.
TECHNICAL DESCRIPTION
The cookers of Hosseven A.S. are suitable to cook on the grill and on the oven and to heat living spaces for some periods or to support
an insuffcient centralized heating system. They are ideal for holiday apartments and weekend houses or as an auxiliary heating system
during the whole year. As fuel, wood logs is used.
The appliance works as an intermittent operating appliance.
The hearth is totally sheathed with single cast iron sheets and it is endowed with a pre-adjusted tertiary air for a better combustion.
Inside there is a thick
flat
grate. The hearth is equipped with a panoramic door with ceramic glass (resistant up to 700
°
C) and outside
tempered. This allows a wonderful view on the burning
flames
. Furthermore, it is thus avoided the output of sparks and smoke.
The heating of the environment is made by irradiation
: through the panoramic glass and the external hot surfaces of the stove,
the heat is radiated into the environment.
The cooker is equipped with controls of primary and secondary air by which it is adjusted the combustion air.
CENTRAL HEATING SYSTEM
Adjust the draught thermostat (Picture-08 no.14) desired temparature ( for example 50
°
C..60
°
C..), push the chimmny flap (Picture.10
no.19) to close. Secondary air (Picture-06/09 no.5) must be open. Keep the draught thermostat primary air inlet open, keep the other
air inlets closed position during central heating period.
TECHNICAL DATA
KH.2545
Defnition
in accordance with
EN 12815
Constructive
system
2
Nominal
power in kW
24
Effciency
in %
85
Water content
in liter
30
Operating temperature max.
in
°
C
90
Operating pressure max. i
n bar
2,5
Smoke outlet
diameter in mm
130
Chimney
height ≥ (m) - dimension (mm)
4 - 200x200 or
Ø
200
Chimney draught
in Pa (mm H2O)
12 (1,2 mm H
₂
O)
Hourly wood consumption
in kg / h (wood with 20% humidity)
2,3
CO
measured at 13% oxygen in %
0,08 - (1000 mg/Nm3)
Exhaust gas emission
in g/s – wood
7,5
Exhaust gas temperature
in °C - wood
280
Hearth opening size
in mm (W x H)
230 x 210
Hearth size
in mm (W x H x D)
285 x 405 x 445
Oven size
in mm (W x H x D)
440 x 290 x 440
Type of grill
Movable - flat
Height
in mm
846
Width
in mm
1044
Depth
in mm
663
Net Weight
in kg
220
±
%5
Fire prevention safety distances
Chapter FIRE SAFETY
5
DO NOT PUT OUT THE FIRE WITH WATER.
When the flue stops burning, have it checked by a specialist to identify any cracks or permeable points.
!