IMPORTANT:
• do not add further wood between one complete load and the next;
• do not suffocate the f
ire by closing the air intakes;
• regular cleaning by a chimney sweep reduces
fne particle emissions.
NORMAL OPERATION
After having positioned the registers correctly, insert the indicated hourly wood load avoiding overloads that cause anomalous
stresses and deformations (according to the instructions on paragraph TECHNICAL DESCRIPTION).
You should always use the product
with the door closed in order to avoid damages due to overheating (forge effect). The inobservance of this rule makes the
warranty expire.
For safety reasons the door of the appliances with constructive system 1, must be opened only for the loading of the fuel or for
removing the ashes, while during the operation and the rest, the door of the hearth must remain closed. The appliances with
constructive system 2 must be connected to their own flue. The operating with open door is allowed under
supervision.
With the controls positioned on the front of the appliance it is possible to adjust the heat emission of the hearth. They have to be
opened according to the calorifc need. The best combustion (with minimum emissions) is reached when, by loading the wood, most
part of the air for combustion flows through the secondary air register.
Never overload the appliance
. Too much fuel and too much air for the combustion may cause overheating and then damage the
stove. You should always use the appliance with the door closed in order to avoid damages due to overheating (forge effect).
The
inobservance of this rule makes the warranty expire
. The adjustment of the registers necessary to reach the rated calorifc yield with
a depression at the stack of 12 Pa 1,2mm of column of water) is the following one: see chapter TECHNICAL DESCRIPTION.
The
appliance works as an intermittent operating appliance
. Besides the adjustment of the air for the combustion, the intensity of the
combustion and consequently the thermal performance of
the device is influenced by the stack. A good draught of the stack requires
a stricter adjustment of air for combustion, while a poor draught requires a more precise adjustment of air for combustion.
ENgLIsH
To verify the good combustion, check whether the smoke coming out from the stack is transparent. If it is white, it means that the
device is not properly adjusted or the wood is too wet; if instead the smoke is gray or black, it signals that the combustion is not
complete (it is necessary a greater quantity of secondary air).
USE OF THE OVEN
Thanks to the air flow for the combustion, the temperature of the oven may become remarkably affected. A
suffcient
flue of the
chimney and of the channels, well cleaned for the flow of burning smokes around the oven are fundamental for a good cooking
result.
Thick cakes and big roasts must be introduced in the lowest level. Flat cakes and biscuits must reach the medium level. The upper
level may be used to heat or grill.
The oven pan and the chrome plated oven grille may be located on different plans (see chapter Technical Description - ACCESSORIES).
When cooking food with high humidity,
cakes with fruit or fruit itself, water of condensation will be produced. During the cooking
process some water vapour in the form of drops of condensed water can deposit onto the top and the side of the door. It is a physical
phenomenon.
By opening the door briefly and carefully (1 or 2 times, or even often in case of longer cooking times) you can let out the st
eam from
the cooking compartment and reduce condensation signifcantly.
OPERATION IN TRANSITION PERIODS
During transition periods when the external temperatures are higher, if there is a sudden increase of temperature it can happen that
the combustion gases inside the flue cannot be completely sucked up.
The exhaust gases do not come out completely (intense smell of gas). In this case, shake the grating more frequently and increase the
air for the combustion. Then, load a reduced quantity of fuel in order to permit a rapid burning (growing up of the flames) an
d the
stabilization of the draught. Then, check that all openings for the cleaning and the connections to the stack are air-tigh.
In case of
doubt, DO NOT operate the product.
MAINTENANCE AND CARE
Check the external air intake, by cleaning it, at least once a year. The stack must be regularly swept by the chimney sweeper. Let your
chimney sweeper in charge of your area check the regular installation of the device, the connection to the stack and the aeration.
10
IMPORTANT: For safety reasons the door of the hearth can be opened only for the loading of the fuel. The
hearth door must always remain closed during operation or rest
!
WARNING: When fuel is added onto the embers in the absence of a flame, a considerable amount of fumes may
develop. Should this happen, an explosive mixture of gas and air may form, and in extreme cases an explosion
may occur. For safety reasons it is advisable to perform a new lighting procedure with the use of small strips.
!