INSTALLATION REGULATIONS
Installation of the Product and auxiliary equipment in relation to the heating system must comply with all current Standards and
Regulations and to those envisioned by the law.
The installation and the relating to the connections of the system, the commissioning and the check of the correct functioning must
be carried out in compliance with the regulations in force by authorised professional personnel with the requisites required by the
law, being national, regional, provincial or town council present in the country within which the appliance is installed, besides these
present instructions.
Installation must be carried out by authorised personnel who must provide the buyer with a system declaration of conformity and will
assume full responsibility for fnal installation and as a consequence the correct functioning of the installed product.
The Product, assembled and ready for the installation, must be connected with a junction to the existing flue of the house. Th
e
junction must be possibly short, straight, horizontal or positioned a little uphill. The connections must be tight.
Before installing the appliance, carry out the following checks:
• UPPER smoke output
- REAR - LATERAL
• verify if your structure can support the weight of the appliance. In case of
insuffcient carrying capacity it is necessary to
adopt appropriate measures, HOSSEVEN A.S. responsibility is limited to the supply of the appliance (See chapter
TECHNICAL
DESCRIPTION
).
• Make sure that the floor can support the weight of the appliance (for ex. distributing weight plate), and if it is made of fl
ammable
material, provide suitable insulation (
DIMENSIONS ACCORDING TO REGIONAL REGULATIONS
).
• Make sure that there is adequate ventilation in the room where the appliance is to be installed, with particular attention
to
windows and doors with tight closing (seal ropes).
• Do not install the appliance in rooms containing collective ventilation ducts, hoods with or without extractor, type B gas
appliances, heat pumps, or other appliances that, operating at the same time, can put the room in depression .
• Make sure that the flue and the pipes to which the appliance will be connected are suitable for its operation.
It is NOT allowed the
connection of various appliances to the same chimney
.
• The installation must be appropriate and has to allow the cleaning and maintenance of the product and the flue.
Your regular local chimney sweep must be informed about the installation of the appliance so that he can check the correct connection
to the chimney
FIRE SAFETY
When installing the product, the following safety measures must be observed:
a) In order to ensure suffcient thermal insulation, respect the minimum safety distance from objects or furnishing components
flammable and sensitive to heat (furniture, wood sheathings, fabrics. etc.) and from materials with flammable structure (see
Picture). All the minimum safety distances are shown on the product data plate and lower values must not be used.
b) In front of the furnace door, in the radiation area there must be no flammable or heat
-sensitive objects or material at a distance of
less than 100 cm. This distance can be reduced to 40 cm where a rear-ventilated, heat-resistant protection device is installed in
front of the whole component to protect.
c) If the product is installed on a non totally refractory floor, one must foresee a f
i
reproof background. The floors made of inflammable
material, such as moquette, parquet or cork etc., must be covered by a layer of no-
inflammable material, for instance ceramic,
stone, glass or steel etc. (size according to regional law). The base must extend at least 50 cm at the front and at least 30 cm at
the sides, in addition to the opening of the loading door (see Picture).
d) No flammable components (e.g. wall units) must be present above the product.
The Product must always operate exclusively with the ash tray inserted. The solid combustion residues (ash) must be collected in
a sealed, fire resistant container. The Product must never be on in the presence of gaseous emissions or vapours (for example glue
for linoleum, petrol etc.). Never deposit flammable materials near the Product.
When using the wrong fuel or one which is too damp, due to deposits present in the flue, a flue f
ire is possible.
4
HOSSEVEN A.S. declines all responsibility for damage to things and/or persons caused by the system. In
addition, it is not responsible for any product modifed without authorisation and even less for the use of
non original spare parts.
!
During combustion, thermal energy is released which leads to considerable heating of the surfaces, doors,
handles,
controls, glass parts, the flue gas pipe and possibly the front part of the appliance. Avoid contact
with these elements unless using suitable protective clothing or accessories (heat resistant gloves, control
devices). Ensure children are aware of these dangers and keep them away from the furnace when it is on.
!
Содержание KH.2545
Страница 1: ...KH 2545 INSTRUCTIONS MANUAL...
Страница 2: ......
Страница 17: ...PICTURE 19 17...
Страница 19: ......