Note: Each relay has a corresponding light. For the condenser fan (X5), compressor
(X4), defrost heater (X1), and door light (X) relays, the light is "on" when the
component is receiving power, and "off" when the component is not receiving
power from the board. For the evaporator fan relay (X3), the opposite is the case;
the light is "off" when the evaporator fan is receiving power, and "on" when the
evaporator fan is not receiving power from the board.
Evercheck Control Board
K9 (red)
K1 (white)
K5 (black)
K4 (red)
(grey/cabinet)
K3 (white)
(orange/defrost)
Alarm Reset Button
Output Test Button
K6 (white)
K (white): Transformer
K8: Communication
Cable (Dual Temp only)
K7: Display Cable
Dip Switch
Thermistors
X3
X
X1
X4
X5
X5 Relay: Condenser Fan
X4 Relay: Compressor
X1 Relay: Defrost Heater
X Relay: Door Light
X3 Relay: Evaporator Fan
2. Control Board Layout