19
HOSHIZAKI EUROPE
B.V.
ALARMS
CODE
DESCRIPTION
RESET
TO CORRECT
Pr1
Cabinet Probe Alarm
automatic
-
check P0
-
check probe integrity
-
check electrical connection
Pr2
Evaporator Probe Alarm
automatic
Pr3
Auxiliary Probe Alarm
automatic
rtc
Clock Alarm
manual
Set date, time and day of the week.
AL
Low Temperature Alarm
automatic
Check A0 , A1 and A2
AH
High Temperature Alarm
automatic
Check A4 and A5
id
Open Door Alarm
automatic
Check i0 and i1
PF
Power Failure Alarm
manual
- touch a key
- check electrical connection
COH
High Condensation Warning
automatic
Check C6
CSd
High Condensation Alarm
manual
- switch the device off and on
- check C7
iA
Multi Purpose input Alarm
automatic
Check the i5 and i6
iSd
High Pressure Alarm
manual
- switch the device off and on
- check i5, i6, i8, i9
LP
Low Pressure Alarm
automatic
Check i5 and i6
C1t
Compressor Thermal Switch
Alarm
automatic
Check i5 and i6
C2t
Second Compressor Thermal
Switch Alarm
automatic
Check i5 and i6
dFd
Defrost Alarm
manual
- touch a key
- check d2, d3 and d11
FUL
SD Card Full Alarm
manual
Free up space on the SD card or replace it
Sd
No SD Card inserted Alarm
manual
Insert the SD card or replace it
Содержание PREMIER 60
Страница 39: ...39 HOSHIZAKI EUROPE B V PREMIER K 70 PREMIER M 70 PREMIER F 70 17 Dimensions...
Страница 40: ...40 HOSHIZAKI EUROPE B V PREMIER KG 70...
Страница 41: ...41 HOSHIZAKI EUROPE B V PREMIER K W80 PREMIER M W80 PREMIER F W80...
Страница 42: ...42 HOSHIZAKI EUROPE B V PREMIER KG W80...
Страница 43: ...43 HOSHIZAKI EUROPE B V PREMIER K 60 PREMIER M 60 PREMIER F 60...
Страница 44: ...44 HOSHIZAKI EUROPE B V PREMIER KG 60...
Страница 45: ...45 HOSHIZAKI EUROPE B V ELECTRICAL WIRING DIAGRAM FOR CABINET REFRIGERATOR MODELS 18 Wiring Diagram...
Страница 46: ...46 HOSHIZAKI EUROPE B V ELECTRICAL WIRING DIAGRAM FOR CABINET FREEZER MODELS...
Страница 47: ...47 HOSHIZAKI EUROPE B V 19 Cooling Diagram...