11
HOSHIZAKI EUROPE
B.V.
Condenser
Use vacuum cleaner or a soft brush to remove dust and stains from the condenser.
Warning:
If users clean the condenser with hard brush,
such as dishwasher brush, the coating of condenser may
peel off.
*Air Filter
To prevent deformation do not wash the air filter hot water above 40
°
Plastic mesh air filters remove dirt or dust from the air and keep the condenser from getting
clogged. If the filters get clogged, the refrigerator/freezer
’
s performance will be reduced.
Check the filters at least twice a month. When clogged or when the temperature controller shows
“
cH" use warm water and a neutral cleaner to wash the filters. Don
’
t operate the unit with the air
filters removed, or the condenser will get clogged, resulting in failure.
1)
Open the front panel and remove the air filter. To prevent injury, don
’
t touch the condenser fins
directly.
2)
Wash the air filter carefully with cold or warm water containing the proper amount of neutral
cleaner. Rinse and dry the air filter thoroughly.
3)
To refit the air filter, put the two tabs into the heat exchanger or fins in condenser and tightly
attach the air filter over the condenser.
Note (*):
Air filter is used in Premier W80, Premier 60 for this manual
Содержание PREMIER 60
Страница 39: ...39 HOSHIZAKI EUROPE B V PREMIER K 70 PREMIER M 70 PREMIER F 70 17 Dimensions...
Страница 40: ...40 HOSHIZAKI EUROPE B V PREMIER KG 70...
Страница 41: ...41 HOSHIZAKI EUROPE B V PREMIER K W80 PREMIER M W80 PREMIER F W80...
Страница 42: ...42 HOSHIZAKI EUROPE B V PREMIER KG W80...
Страница 43: ...43 HOSHIZAKI EUROPE B V PREMIER K 60 PREMIER M 60 PREMIER F 60...
Страница 44: ...44 HOSHIZAKI EUROPE B V PREMIER KG 60...
Страница 45: ...45 HOSHIZAKI EUROPE B V ELECTRICAL WIRING DIAGRAM FOR CABINET REFRIGERATOR MODELS 18 Wiring Diagram...
Страница 46: ...46 HOSHIZAKI EUROPE B V ELECTRICAL WIRING DIAGRAM FOR CABINET FREEZER MODELS...
Страница 47: ...47 HOSHIZAKI EUROPE B V 19 Cooling Diagram...