33
Example: Hydrogen Peroxide (3% Solution) Spray
Daily
Keep exterior surfaces of the dispenser (nozzle, nozzle guard, front plate dispensing area, drain pan top, drain pan
bottom) clean by using a clean, damp cloth. While wearing sanitary gloves, sanitize the exterior surfaces with a
hydrogen peroxide (3% solution) and allow the surface to air dry. When cleaning and sanitizing the touch buttons, be
sure to power off the dispenser to prevent accidentally dispensing water. Additionally, it is important to keep the drain
pan clean of debris. Remove any as soon as it is noticed.
Weekly
Use a vacuum to clean out dust from all the vents.
Pour hot water into the drain pan to keep the drain open (if the drain pan is connected to a drain line).
Every Six Months
NOTICE:
These operations must be carried out by an authorized technician and should be done every time the All-in-
One filters and alkaline chamber are replaced.
1) Replacing the Nozzle Tip:
A. Disconnect the power so that water is not accidentally dispensed.
B. While wearing sanitary gloves, remove the nozzle cap by unscrewing it counterclockwise. Remove the
aerator and o-ring from the nozzle cap. A special tool is available from Hoshizaki.
C. Insert new aerator and o-ring (both available as service parts from Hoshizaki) into the nozzle cap and screw
the assembly back into the nozzle.
Nozzle Tip