18
•
Locate the gas tubing (1/4”) as found in the installation kit.
•
Attach a CO
2
regulator (as provided in the installation kit) to the external CO
2
canister (not provided) by turning the
nut to the right while holding the regulator.
IMPORTANT:
Ensure that the main valve on the external CO2 canister
is completely closed.
•
Connect the CO
2
regulator using the 1/4” CO
2
tube, to the elbow quick connector (1/4”) in the “CO
2
INLET” at the
back of the DWM-20A appliance.
•
Open the main valve on the external CO
2
canister very gently to avoid fast release of gas.
•
Then, use the CO
2
regulator (see installation kit) to adjust the pressure. Turn the blue handle knob located on the
front side of the CO
2
regulator. Set the pressure to your desired fizziness level (typically around 55 to 65 psi). After
the pressure is set, push the blue knob in, to lock the arrow right at the selected gas pressure.
•
See Figure 6 below. For fine tuning go on page 29.
WARNING:
THE CO
2
TANK MUST BE SECURED WITH A CHAIN OR RESTRAINT (P) IN AN UPRIGHT POSITION
AS INDICATED ON PAGE 14 OF THIS MANUAL.
•
At this point, locate the main electrical power socket and the main electrical power supply switch at the back of
the DWM-20A, plug in the dispenser and switch the main electrical power ON (see fig 7 and fig 8 below).
IMPORTANT:
do not turn on hot water power yet (the red switch behind the DWM-20A).
IMPORTANT:
if the DWM-20A was NOT transported upright, make sure the DWM-20A has sat still in its position
for at least 2 hours before turning on main power. This is to ensure the refrigerant has had time to settle.
Electrical Cable
Main Electrical Power Socket
Main Power Switch
Hot Water Switch
Child Safety Switch