6.7
Connecting Python
Connect Python to Chiller and Dispenser.
Caution
NOTE: The R8E Superchiller is rated to operate with a
maximum of 90m of python connected at 32
°C
.
Exceeding manufacturer’s ratings may cause damage to the
Superchiller and void warranty.
Connect the Python to Chiller and Dispenser.
Refer to Python and Dispenser specifications for connection data.
Superchiller can be supplied with 5 pumps, dual carbonator, or 3 pumps single carbonator; python
should be connected to Chiller as follows:
5 Pump
3 Pump
SODA
RETURN A
WATER
RETURN
SODA
RETURN B
SODA
RETURN A
WATER
RETURN
SODA
SUPPLY A
WATER
SUPPLY
SODA
SUPPLY B
SODA
SUPPLY A
WATER
SUPPLY
Important
: Ensure lines from python to Superchiller connections are insulated to prevent
condensation.
Note
: For additional Soda reserve on short python lengths used in high volume accounts, it may be
necessary to extend the soda circuit by connecting the 2 spare lines in the python onto the soda
return line (i.e. double pass of soda circuit out and back from dispense point to soda return).
6.8 Plumbing the drain and CO
2
exhaust
The 19mm overflow drain tube exiting from the base of the tank should be plumbed to a suitable
drain, installation in accordance with AS/NZS 3500.1 and AS/NZS 3500.2.
The 6mm barb labelled as CO2 EXHAUST should be plumbed to an outside safe area.