14. Certificate of Warranty 

It is the policy of Hoshizaki to provide to its current customers, warranty for all equipment supplied and 

installation work performed within a specified period. 

 

Parts and Equipment 

Lancer provides a warranty period of twelve (12) months from the date of original invoice for all 

manufactured parts and the associated labour. Repair or replace of defective parts will be at the sole 

discretion of Lancer.  

 

Changeover parts will be invoiced to the customer at the customers normal purchase cost and upon return 

of the warranty item and validation of the claim, the invoice will be credited. 

 

Installations 

Lancer provides a warranty period of twelve (12) months from the date of final invoice for workmanship after 

the completion of any installation work, provided the parts and labour are completed by Lancer or its 

subcontractor. 

 

Labour 

Lancer will not normally cover any labour costs associated with a warranty claim. Subject to the approval of 

the Divisional Sales Manager, Lancer may choose to reimburse the customer for some or all labour costs 

associated with a warranty claim. Any claim for labour costs must be authorized by Lancer prior to the work 

being undertaken. 

 

Exclusions 

Lancer will not accept any liability or cost associated with any consequential losses (such as loss of syrup or 

beer), loss of profit or damage to property as a result of faulty product. 

 

Warranty shall not apply: 

a)  If in the opinion of Lancer, the equipment has been used in a situation the equipment has not been 

designed for; 

b)  If in the opinion of Lancer, the equipment has been subject to abuse, negligence or accident; 

c)  If connected to improper, inadequate or faulty power, water or drainage service or operated using 

incorrect, insufficient or contaminated lubricants, coolants, refrigerants or additives; 

d)  Where the product is installed, maintained or operated otherwise than in accordance with the 

instructions supplied by Lancer; 

e)  Where the product has been damaged by foreign objects; 

f) 

Where the product has been serviced, repaired, altered or moved otherwise than by Lancer or its 

nominees or using other than Lancer approved replacement parts. 

 

 

Содержание Lancer Superchiller Remote R8E V2 Series

Страница 1: ...lancerbeverage com 230V 50Hz Installation Operation Service Manual R8E V2 Superchiller Remote...

Страница 2: ...cerbeverage com Page 2 of 27 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000009 Images are for illustration purposes only as product may vary No 027 7 March 20...

Страница 3: ...Superchiller 9 6 5 Connecting Superchiller to Remote Condensing Unit 9 6 6 Electrical Connection 9 6 7 Connecting Python 10 6 8 Plumbing the drain and CO2 exhaust 10 6 9 Connecting to water supply 11...

Страница 4: ...ice equipment Hoshizaki Lancer s head office and manufacturing base is located in Adelaide SA with branch offices and warehousing facilities in Sydney NSW Melbourne VIC Brisbane QLD Perth WA and Auckl...

Страница 5: ...Empty 123 kg 145kg Operating 305 kg 327kg Ice bank Weight 75 kg Water Bath Capacity 180 litres Construction Stainless Steel Agitator Motor 25W 230 VAC 1 Phase Ice bank Control Electronic Carbonation L...

Страница 6: ...e machine 5 2 Recognise Safety Alert Symbols The safety alert symbol precedes Warning and Caution notes throughout this manual To prevent personal injury or damage to the machine these alerts must be...

Страница 7: ...pressure De pressurise before performing any work on the system Warning ALL WIRING AND PLUMBING MUST CONFORM TO LOCAL AND NATIONAL CODES Warning SUPERCHILLER MUST BE ISOLATED FROM ELECTRICAL SUPPLY BE...

Страница 8: ...s is recommended to protect hands from potential injury from sharp edges The Superchiller must always be handled in a vertical position Carefully unpack the Lancer R8E Superchiller from the shipping c...

Страница 9: ...hould be sized correctly to provide a minimum return vapour velocity of 7 5m s vertical risers and 3 5m s horizontal sections Suction line pressure drop should comply with industry standard guidelines...

Страница 10: ...hould be connected to Chiller as follows 5 Pump 3 Pump SODA RETURN A WATER RETURN SODA RETURN B SODA RETURN A WATER RETURN SODA SUPPLY A WATER SUPPLY SODA SUPPLY B SODA SUPPLY A WATER SUPPLY Important...

Страница 11: ...d be within 7 C to 32 C 6 10 Connecting to CO2 supply Warning As carbon dioxide CO2 displaces oxygen prevention of CO2 leaks is paramount If a leak is suspected immediately ventilate the contaminated...

Страница 12: ...rom BIB containers Immerse all disconnects in warm water and clean using a nylon bristle brush Rinse with clean water Prepare sanitising solution according to manufacturer s instructions Attach saniti...

Страница 13: ...ed in Clause 3 3 2 of AS 5034 to handle cylinders Should the valve become accidentally damaged or broken off a CO2 cylinder can cause serious personnel injury Quarterly The Superchiller should be conn...

Страница 14: ...rs Immerse all disconnects in warm water and clean using a nylon bristle brush Rinse with clean water Prepare sanitising solution according to manufacturer s instructions Attach sanitising fittings to...

Страница 15: ...Page 15 of 27 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000009 Images are for illustration purposes only as product may vary No 027 7 March 2013 8 Postmix Ci...

Страница 16: ...16 of 27 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000009 Images are for illustration purposes only as product may vary No 027 7 March 2013 8 2 Twin Carbona...

Страница 17: ...lancerbeverage com Page 17 of 27 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000009 Images are for illustration purposes only as product may vary No 027 7 Mar...

Страница 18: ...set CO2 to 550 kpa Check carbonator control using procedure on page 25 Replace control or probe if defective If strainer and filter are clear and line valves are fully open noisy pump operation indica...

Страница 19: ...m of 172 kpa water supply pressure is required Check function setting of CO2 regulator Faucet delivers CO2 gas continuously Carbonator pump will not run due to power failure or low voltage Pump water...

Страница 20: ...s present on terminals N A ON 1 ON 2 terminals Work should only be performed by fully trained certified Electrical Plumbing Refrigeration Technicians 1 Remove the ice bank probe connections from termi...

Страница 21: ...230VAC is present on terminals N A ON 1 ON 2 Work should only be performed by fully trained certified Electrical Plumbing Refrigeration Technicians 1 Remove the carbonator probe connections from termi...

Страница 22: ...83 BACKFLOW PREV WATTS 9DB AUS 5 08000002 CARBONATOR RELIEF VAVLE 6 23822336 LANCER CARBONATOR ASSY 7 63000163 COIL ASSY PRECHILL B 8 79000332 CHECK VALVE S S 10MM BARB 9 79000739 BALL VALVE S S WATER...

Страница 23: ...lancerbeverage com Page 23 of 27 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000009 Images are for illustration purposes only as product may vary No 027 7 Marc...

Страница 24: ...V2 2 79000556 CLAMP B TUBE R8E 3 79000555 CLAMP A TUBE R8E 4 61616653 ICE PROBE BRACKET ASSY R8 5 16522334 ICE BANK PROBE 6 61000544 CONDUIT CABLE R8E V2 7 83000114 TX VALVE DANFOSS TUBE 03 8 8300027...

Страница 25: ...cerbeverage com Page 25 of 27 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000009 Images are for illustration purposes only as product may vary No 027 7 March 2...

Страница 26: ...abour Lancer will not normally cover any labour costs associated with a warranty claim Subject to the approval of the Divisional Sales Manager Lancer may choose to reimburse the customer for some or a...

Страница 27: ...ightness and correct wiring of harness Carbonator and plumbing pressure tested Check for leaks on pumps clamps welds strainers carbonator fittings and all joints Check check valve and strainer indicat...

Отзывы: