54
[b] SANITIZING PROCEDURE - Following Cleaning Procedure
1) Dilute a 5.25% Sodium Hypochlorite solution (chlorine bleach) with water. [Add 0.5 fl. oz.
(15 ml.) of sanitizer to 1 gal. (3.8 l.) of water.]
2) Wash the bin liner, the Thermostat Bracket, the Water Tank Brackets and the Water
Tank using the above sanitizing solution.
3) Rinse the above parts thoroughly with water.
4) Place the Thermostat Bracket, the Water Tank Brackets, the Water Tank and the Tank
Drain Hose in their correct positions.
5) Remove the Cube Guide.
6) Pour the sanitizing solution into the Water Tank.
7) Place the Cube Guide in its correct position.
8) Move the Control Switch to the “WASH” position.
9) Shut the Door.
10) After 15 minutes, move the Control Switch to the “OFF” position.
11) Open the Door.
12) Remove the Cube Guide and the Overflow Pipe to drain the Water Tank. Place the
Overflow Pipe and the Cube Guide in position.
13) Repeat the above steps 11) through 15) in “[a] CLEANING PROCEDURE” two times to
rinse thoroughly.
14) Flush the Storage Bin with water.
15) Move the Control Switch to the “ICE” position, and start the automatic icemaking
process.
16) Place the Front Panel in position, and shut the Door.
Содержание KM-150BAF
Страница 5: ...5 I SPECIFICATIONS 1 KM 150BAF ...
Страница 6: ...6 2 KM 150BWF ...
Страница 7: ...7 II GENERAL INFORMATION 1 CONSTRUCTION a KM 150BAF ...
Страница 8: ...8 b KM 150BWF ...
Страница 14: ...14 Control Products HOSHIZAKI001 Board ...
Страница 15: ...15 Control Products HOS 001A Board ...
Страница 23: ...23 TEST PROGRAM OF ALPINE CONTROLLER BOARD ...
Страница 25: ...25 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERANT CIRCUIT a KM 150BAF ...
Страница 26: ...26 b KM 150BWF ...
Страница 30: ...30 4 PERFORMANCE DATA a KM 150BAF Air cooled ...
Страница 31: ...31 b KM 150BWF Water cooled ...