34
2. FLOWCHART
[a] RTC SERIES
PROBLEM
PROBLEM
POSSIBLE CAUSE (numbers corresponding to "3. COMPONENTS")
No refrigeration
Compressor will not start
No temp indication
[1] Fuse
Blown out
[2] Controller
Open circuit, connector unplugged
E1 error indication
[4] Interior Thermistor
Abnormal resistance, bad contact
No error indication
[4] Interior Thermistor
Abnormal resistance, bad contact
[7] Compressor
Winding open, electrical part defective
Compressor starts and stops
No error indication
Ambient temp too high
immediately
Condensing capacity insufficient
Heat source, ventilation
[15] Air Filter
Clogged
[8] Condenser Fan Motor
Locked, open circuit
[4] Interior Thermistor
Location
[7] Compressor
Locked, etc
Compressor runs with
E2 error indication
[5] Defrost Thermistor
Abnormal resistance, bad contact
no refrigeration
(frosted evaporator)
No error indication
Ambient temp too high
Condensing capacity insufficient
Heat source, ventilation
[15] Air Filter
Clogged
Internal load too large
Door gap
[4] Interior Thermistor
Location
[9] Interior Fan Motor
Open circuit, defective
[2] Controller
Defective
[13] Refrigeration Circuit
Capillary, drier
[14] Refrigerant Leak
[8] Condenser Fan Motor
Locked, open circuit
[7] Compressor
Defective
Poor refrigeration
Slow refrigeration
Set point is reached
Interior overloaded
Set point is not reached
See "Compressor runs with no refrigeration" above
Normal temp indication
Interior overloaded
with poor refrigeration
Heat load inside
[9] Interior Fan Motor
Open circuit, defective
[2] Controller
Defective
[4] Interior Thermistor
Abnormal resistance, bad contact, location
Frosted evaporator
Defrost cycle setting readjusted
Too long
[5] Defrost Thermistor
Abnormal resistance
[16] Drain Hose
Without trap structure, without hose
Compressor runs continuously
[4] Interior Thermistor
Location
Normal temp indication
[4] Interior Thermistor
Abnormal resistance
[2] Controller
Defective
No error indication
Cold air outlet loaded
Cold air inlet blocked
Ambient temp too low
Abnormal noise
[7] Compressor
[8] Condenser Fan Motor
[9] Interior Fan Motor
[2] Controller
Beep with thermistor error [4] [5]
Excessive
refrigeration
Содержание FTC-120MDA
Страница 6: ...3 2 DIMENSIONS SPECIFICATIONS a RTC 120MNA ...
Страница 7: ...4 b RTC 120MDA ...
Страница 8: ...5 c RTC 150MNA ...
Страница 9: ...6 d RTC 150MDA ...
Страница 10: ...7 e RTC 180MNA ...
Страница 11: ...8 f RTC 180MDA ...
Страница 12: ...9 g FTC 120MNA ...
Страница 13: ...10 h FTC 120MDA ...
Страница 14: ...11 i FTC 150MNA ...
Страница 15: ...12 j FTC 150MDA ...
Страница 16: ...13 k FTC 180MNA ...
Страница 17: ...14 l FTC 180MDA ...
Страница 18: ...15 II TECHNICAL INFORMATION 1 WIRING DIAGRAM a RTC SERIES ...
Страница 19: ...16 b FTC 120MNA FTC 120MDA FTC 150MNA ...
Страница 20: ...17 c FTC 150MDA FTC 180MNA FTC 180MDA ...