38
3. COMPONENTS
CHART
NO.
COMPONENT
CHECK
REMEDY
[1]
Fuse
Blown out
Replace
[2]
Controller
Open circuit
Correct or replace
Input/output (interior fan motor)
Replace
See wiring label
Connector disconnected
Correct
Connector dusty/dirty
Remove
7 segment display partially/totally off
Replace
Electronic parts defective/burnt out
[3]
Relay
Fast-on terminal/pin disconnected
Correct
Connector dusty/dirty
Remove
Open circuit
Correct
Output to each load
Replace
Check with wiring diagram/timing chart
Abnormal noise
[4]
Interior Thermistor
Location (holder in front of evaporator)
Correct
Disconnected, replaced with defrost thermistor, etc
Incorrect temp indication
Immerse in ice water to check resistance
(25 - 30k) Replace if necessary
(RTC series)
Short circuit (temp displayed as "E1")
Clean/dry connector
Replace
Open circuit (temp displayed as "E1")
Replace
(FTC series)
Short circuit (temp displayed as "HHH")
Clean/dry connector
Replace
Open circuit (temp displayed as "LLL")
Replace
[5]
Defrost Thermistor
Location (plug in from evaporator back)
Correct
Disconnected, replaced with interior thermistor, etc
Abnormal resistance
Immerse in ice water to check resistance
(25 - 30k) Replace if necessary
(RTC series)
Short circuit (temp displayed as "E2")
Clean/dry connector
Replace
Open circuit (temp displayed as "E2")
Replace
(FTC series)
Short circuit (temp displayed as "HHH")
Clean/dry connector
Replace
Open circuit (temp displayed as "LLL")
Replace
[6]
Pressure Switch
Open circuit
Replace
[7]
Compressor
Resistance between terminals (at 25
˚
C)
Replace
Compressor Winding resistance (
Ω
)
Start Run
AZ0411Y 26.85 11.10
AE2416ZK
24.27 5.71
AE2420ZK-SR
17.70 6.10
AE2432ZK
8.56
3.26
Abnormal noise
Insufficient compression (discharge temp too low)
Replace if no gas leaks
Compressor electrical part defective
Replace
- Run/start capacitor ruptured/deformed
- Capacitor defective
Check resistance between terminals
Gradually reduces: No problem
0 from start: Defective
- Starter defective
Loose terminal, no conductivity, damaged
- Overload relay defective
Loose terminal, no conductivity, damaged
[8]
Condenser Fan Motor Open circuit
Correct
Locked (not rotating with voltage)
Replace
Abnormal noise
Burning smel
l
[9]
Interior Fan Motor
Open circuit
Correct
Locked (not rotating with voltage)
Replace
Abnormal noise
Burning smel
l
Содержание FTC-120MDA
Страница 6: ...3 2 DIMENSIONS SPECIFICATIONS a RTC 120MNA ...
Страница 7: ...4 b RTC 120MDA ...
Страница 8: ...5 c RTC 150MNA ...
Страница 9: ...6 d RTC 150MDA ...
Страница 10: ...7 e RTC 180MNA ...
Страница 11: ...8 f RTC 180MDA ...
Страница 12: ...9 g FTC 120MNA ...
Страница 13: ...10 h FTC 120MDA ...
Страница 14: ...11 i FTC 150MNA ...
Страница 15: ...12 j FTC 150MDA ...
Страница 16: ...13 k FTC 180MNA ...
Страница 17: ...14 l FTC 180MDA ...
Страница 18: ...15 II TECHNICAL INFORMATION 1 WIRING DIAGRAM a RTC SERIES ...
Страница 19: ...16 b FTC 120MNA FTC 120MDA FTC 150MNA ...
Страница 20: ...17 c FTC 150MDA FTC 180MNA FTC 180MDA ...