![Hoshizaki FM-120KE-50-HC Скачать руководство пользователя страница 51](http://html1.mh-extra.com/html/hoshizaki/fm-120ke-50-hc/fm-120ke-50-hc_service-manual_2165200051.webp)
48
48
7) Remove the screws and the valve from the bracket.
8) Install the new valve, and braze the capillary tube.
9) Install the new drier.
10) Check for leaks using nitrogen gas (10 bar) and soap bubbles.
11)
Connect the flare-connections.
12) Evacuate the system, and charge it with refrigerant. See the nameplate for the required
refrigerant charge.
13) Open the water supply tap.
14) Plug in the icemaker.
15) Check for water leaks.
16) If necessary, adjust the valve.
17) Replace the panels in position.
7. EVAPORATOR ASSEMBLY
See the exploded view under “III. 3. ICEMAKING MECHANISM”.
1) Push the stop button to drain the water in the evaporator.
2) Disconnect the power source.
3) Remove the panels.
4) Remove the three hex head bolts, and take off the spout from the evaporator.
5) Remove the bin control switch.
6) Remove the spout gasket at the top of the evaporator.
CUTTER
7) Remove the bolt and lift off the cutter.
BELT HEATER
8) Detach the spring, and remove the belt heater.