Non-Interlock Errors
Code
Error
Condition
Operation
Reset
Check/Repair
CM
Time
“- -”
Microcomputer
Read/Write
Error
Microcomputer fails to
read/write properly.
Memory circuit not
available.
Replace controller
board.
Error records
and compressor
operating hours not
available on display
c0
Icemaking
Water Leak
After initial water supply,
float switch trips at lower
float level within 5 minutes
after gear motor starts and
before compressor starts.
Whole unit stops. Flush
water valve turns ON for 1
second, then turns OFF.
Unit restarts.
Error record only.
Water leak from
water circuit
(reservoir, hoses,
mechanical seal,
flush water valve),
float switch
c1
Low Water
Water supply continues
for more than 90 seconds,
or float switch trips at
lower float level and does
not reset for more than
60 seconds after water
supply.
Whole unit stops until
reservoir fills up. Only
control water valve
operates intermittently for
5 minutes.
Automatically resets
after reservoir fills
up.
Water supply
interruption, control
water valve not
opening, flush water
valve not closing,
float switch, water
leak
c2
Abnormal High
Side Pressure
Pressure switch stays
OFF for 5 seconds or
condenser thermistor
reads higher than set point
for 5 seconds.
Whole unit stops.
Automatically resets
after pressure
switch turns ON
or condenser
thermistor reads
lower than set point.
Condenser clogged,
cooling water circuit,
refrigeration circuit
c3
Abnormal Low
Voltage
Voltage stays below setting
for more than 1 second
with compressor ON and
control water valve OFF.
Whole unit stops.
Automatically resets
after voltage stays
above reset setting
for 2 minutes.
Supply voltage
c4
Drain Error
Float switch trips at upper
float level in 10 minutes
after flush water valve
turns ON.
N/A
Error record only.
Flush water valve
not opening, control
water valve not
closing
c5
Gear Motor
Error
Rotation rate reduces.
Whole unit stops.
Automatically resets
after 30 minutes.
Gear motor
overloaded
While gear motor is
running, voltage detection
signal is not input to
controller board.
c7
Evaporator
Outlet
Temperature
Decrease
Evaporator outlet
temperature decreases.
Indication only.
Automatically
resets.
Evaporator inside
not clean, extruding
head not clean,
heater circuit open
PC
Periodic Parts
Replacement
Compressor operating
hours reach 20,000 hours.
[20,000 hours] “PC” starts
flashing.
[20,500 hours] Whole
unit stops but can be
restarted by turning OFF
and ON power supply.
[21,000 hours] Whole unit
stops again and cannot
be restarted.
After replacing
parts, reset
compressor
operating hours.
Replace extruding
head (upper
bearing) and
mechanical seal.