29
[e] RESETTING ERROR LOG
With the operation switch in the “OFF” position, press and hold the stop and maintenance
A buttons. Move the operation switch to the “ON” position. Release the buttons when the
display shows the ice mode. Now the error log is reset. Do not reset more than necessary.
[f] RESETTING COMPRESSOR OPERATING HOURS
Note: This operation should be performed only when the display shows “PC”.
With the power switch turned off, press and hold the ice, stop and maintenance A buttons.
Move the operation switch to the “ON” position. Release the buttons when the display
shows the ice mode. Now the compressor operating hours are reset.
When the compressor starts in 15 seconds after the water supply cycle ends, the error
log is not set to be updated. After resetting the compressor operating hours, move the
operation switch to the “OFF” position, turn off the power switch, and turn it back on.