78
<STEP 2>
Use the cleaning solution to remove lime deposits in the water system.
1) Turn off the power supply.
2) Close the Water Supply Line Shut-off Valve.
3) Remove all ice from the Storage Bin.
4) Remove the Front Panel and the Top Panel.
5) Move the Flush Switch to the “FLUSH” position.
6) Turn on the power supply and drain out all water from the water line.
7) Turn off the power supply.
8) Remove the Control Water Valve by releasing the Fitting Nut. Do not lose the Packing.
9) Remove the Cover of the Reservoir.
10) Fill the Reservoir with the cleaning solution.
11) Replace the Cover of the Reservoir and the Control Water Valve in their correct positions.
Note:
This unit is designed to start operating when the Reservoir is filled with water.
12) Move the Flush Switch to the “ICE” position.
13) Replace the Top Panel and the Front Panel in their correct positions.
14) Allow the icemaker to sit for about 10 minutes before the operation. Then, turn on the
power supply, and make ice using the solution until the icemaker stops icemaking.
15) Remove the Front Panel.
16) Move the Flush Switch to the “FLUSH” position to drain the cleaning solution.
17) Move the Flush Switch to the “ICE” position.
18) Replace the Front Panel in its correct position.
19) Open the Water Supply Line Shut-off Valve, and supply water to the Reservoir.
20) Turn off the power supply when the Gear Motor starts.
21) Drain out all water from the water line. See 4) through 7).
Содержание F-2000MLF
Страница 14: ...14 2 CONDENSER UNIT URC 20F...
Страница 16: ...16 II GENERAL INFORMATION 1 CONSTRUCTION F 2000MLF C...
Страница 17: ...17 F 2000MRF3 C F 2000MRF C...
Страница 18: ...18 F 2000MWF C...
Страница 20: ...20 F 2000MWF F 2000MRF C...
Страница 21: ...21 F 2000MLF C...
Страница 22: ...22 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERATION CIRCUIT F 2000MLF C...
Страница 23: ...23 F 2000MRF3 C...
Страница 24: ...24 F 2000MWF C...
Страница 25: ...25 2 WIRING DIAGRAMS F 2000MLF C...
Страница 26: ...26 F 2000MRF3 C...
Страница 27: ...27 F 2000MWF C...
Страница 28: ...28 F 2000MRF C...
Страница 30: ...30 b When Reservoir has been filled Gear Motor starts immediately...
Страница 31: ...31 c Compressor starts F 2000MLF C only two solenoid valves open about 60 sec after Gear Motor starts...
Страница 33: ...33 e Low Water Except Water cooled Model where Compressor will operate intermittently...
Страница 39: ...39...
Страница 69: ...69...