WARNING
• Wear appropriate personal protective equipment (PPE) when servicing the
appliance.
• Technician must utilize a combustible gas leak detector at all times.
• Notify everyone in the immediate area that you are working with flammable
refrigerant.
• Do not work on appliance in a confined space. Confirm area is well ventilated.
• Identify and eliminate all possible ignition points in a 10 ft. (3 m) area around service
area.
• Do not use mechanical devices to defrost.
• Use non-sparking tools.
• Class B dry chemical fire extinguisher or equivalent must be available.
• Do not pressurize system above 200 PSIG during leak check procedure or prior to
evacuating refrigeration system.
• This appliance should be diagnosed and repaired only by qualified service
personnel to reduce the risk of death, electric shock, serious injury, or fire.
• To reduce the risk of electric shock, do not touch the plug with damp hands.
• Unplug the appliance from the electrical outlet before servicing.
• Make sure all food zones in the appliance are clean after the appliance is serviced.
Содержание EF1A-FS
Страница 1: ...FREEZER Service Manual ER1A FS ER2A FS EF1A FS EF2A FS Issued 07 26 2019 Revised 07 14 2020...
Страница 28: ...28 Model Run Capacitor Starting Capacitor ER1A FS 15 F 250 V 250 F 160 V B Wiring Diagram...
Страница 29: ...29 Model Run Capacitor Starting Capacitor EF1A FS 10 F 250 V 150 F 160 V...
Страница 30: ...30 Model Run Capacitor Starting Capacitor ER2A FS 15 F 250 V 250 F 160 V...
Страница 31: ...31 Model Run Capacitor Starting Capacitor EF2A FS 30 F 250 V 200 F 160 V...