14
1. Troubleshooting
a) Not Cooling
Check for correct appliance installation per the instruction manual and proper voltage per
appliance nameplate.
Not Cooling - Possible Cause
1. Power Supply
a) Unplugged, off, blown fuse, tripped or defective circuit
breaker. On three-section receptacle box, only top
receptacles have power.
b) Loose connection.
c) Not within specifications.
2. Cord and Plug
a) Loose connection.
b) Defective.
3. Control Module See “ll.B.1.g) Alarm
Safeties” and “ll.C. Control Module
Check”
a) In alarm.
b) Defective.
4. Door Switch
a) Not engaged.
b) Defective.
5. Door Switch Relay
a) Loose connection.
b) Defective.
6. Fan Motors
a) Defective.
b) Dirty condenser.
7. Wiring
a) Loose connection.
b) Faulty.
8. Compressor Relay (ptc)
a) Defective.
9. Compressor External Protector a) Dirty condenser.
b) Condenser fan motor not operating.
c) Compressor capacitor or start relay defective.
d) Defective.
10. Compressor
a) Defective.
b) Low voltage.
11. Condenser
a) Dirty.
12. Refrigerant/Refrigerant Lines
a) Low or overcharged.
b) Refrigerant leak.
c) Refrigerant lines restricted.
13. Filter Drier
a) Defective.
Содержание EF1A-FS
Страница 1: ...FREEZER Service Manual ER1A FS ER2A FS EF1A FS EF2A FS Issued 07 26 2019 Revised 07 14 2020...
Страница 28: ...28 Model Run Capacitor Starting Capacitor ER1A FS 15 F 250 V 250 F 160 V B Wiring Diagram...
Страница 29: ...29 Model Run Capacitor Starting Capacitor EF1A FS 10 F 250 V 150 F 160 V...
Страница 30: ...30 Model Run Capacitor Starting Capacitor ER2A FS 15 F 250 V 250 F 160 V...
Страница 31: ...31 Model Run Capacitor Starting Capacitor EF2A FS 30 F 250 V 200 F 160 V...
Страница 32: ...SERIES 618 Hwy 74 South Peachtree City GA 30269 USA P 800 227 3172 www economyseries com MAN 342 R...