13
NOTICE
• Normal operating ambient temperature range is from:
Refrigerator and freezer 45°F to 90°F (7°C to 32°C).
• Ventilation is required from the bottom front of the appliance. Keep this
area open and clear of any obstructions. Adjacent cabinets and counter
top can be installed around the appliance as long as the front grille
remains unobstructed.
• The appliance must not be located next to ovens, grills, or other high
heat producing equipment.
• The appliance must not be located in a corrosive environment.
The diagnostic table is a sequence check that allows you to diagnose the electrical
system and components. Before proceeding, check for correct installation and proper
voltage per nameplate. Always choose a neutral (W) to establish a good neutral
connection when checking high voltages.
IMPORTANT
The maximum allowable voltage variation is ±10 percent of the nameplate rating.
115VAC is used as a reference voltage when checking voltage to components.
Voltage may vary depending on power supply.
Factory Default Temperature Setpoint:
• Refrigerator 33°F (0.5°C)
• Freezer -5°F (-20.5°C)
Temperature Display Scale: °F (°C)
• There is a minimum 3-min. Comp on time and 3-min. Comp off time.
Содержание EF1A-FS
Страница 1: ...FREEZER Service Manual ER1A FS ER2A FS EF1A FS EF2A FS Issued 07 26 2019 Revised 07 14 2020...
Страница 28: ...28 Model Run Capacitor Starting Capacitor ER1A FS 15 F 250 V 250 F 160 V B Wiring Diagram...
Страница 29: ...29 Model Run Capacitor Starting Capacitor EF1A FS 10 F 250 V 150 F 160 V...
Страница 30: ...30 Model Run Capacitor Starting Capacitor ER2A FS 15 F 250 V 250 F 160 V...
Страница 31: ...31 Model Run Capacitor Starting Capacitor EF2A FS 30 F 250 V 200 F 160 V...
Страница 32: ...SERIES 618 Hwy 74 South Peachtree City GA 30269 USA P 800 227 3172 www economyseries com MAN 342 R...