6
ENGLISH
[Connection to the drain]
*
Attach the grey flexible drain hose (accessory) to the fitting at the bottom of the drain pan. Use the hose clamp (accessory) to
obtain a leak free joint.
* Drain lines should not be installed directly to the sewer system. A vertical air gap of a minimum of 5 cm should be between the
end of the drain hoses from the ice dispenser and the floor drain.
* The ice dispenser drain is gravity flow, ensure drain hose has an adequate pitch or fall
.
II. OPERATING INSTRUCTIONS
CAUTION
Do not put your hands into the dispensing outlet. The icemaking mechanism may
suddenly move, resulting in injury.
NOTICE
All parts are factory-adjusted. Improper adjustments may result in failure.
If the unit is turned off, wait for at least 3 minutes before restarting the ice dispenser to prevent damage to the compressor.
Periods of 5 to 6 hours without dispensing ice could result in wet ice or an ice bridge forming in the storage bin. Always
turn off the ice making switch, and remove ice from the storage bin within 2 hours. Soggy and sticky ice should be removed
continuously as produced.
This ice dispenser is programmed to suspend ice dispensing action when the push lever/dispense switch is continuously pressed
for more than 2 minutes. Also, pressing and releasing the push lever/dispense switch repeatedly for extended periods may cause
the protector to stop the ice dispenser.
HYGIENE
This ice dispenser is designed to produce edible ice. To keep the ice dispenser hygienic, follow the instructions in “III. 1.
CLEANING”.
Downgrade
GOOD
BAD
Upgrade
BAD
Drain Hose
Hose Clamp
Water Supply
Inlet G3/4
Drain Outlet
Drain
5cm air gap
Inlet Hose
Water Supply Tap
Inlet Hose