5. INSTALLATION

CAUTION

Incorrect installation can cause harm to people, animals or other items, for which the manufacturer cannot be held 

responsible.
Keep the adjustable leg height within 0 to 15 mm to prevent reduction in leg strength or injury caused by a falling adjuster. 

* Place the ice dispenser on a firm level surface at counter top height.

* Turn the leg adjusters to level the unit in both the left-to-right and front-to-rear directions

  (tilt limit: within 1 cm).

6. ELECTRICAL CONNECTIONS

WARNING

THIS APPLIANCE MUST BE EARTHED

To prevent possible severe electrical shock to individuals or extensive damage to the unit, the icemaker must be connected 

via the flexible supply cord supplied with the icemaker to an appropriate outlet socket installed in accordance with local codes 

and regulations i.e. AS / NZS 3000.
Disconnect the main power supply before any maintenance, repairs or cleaning is undertaken.

* It is recommended that these appliances are connected to a separate 240VAC supply, protected by an appropriate circuit 

breaker and Residual Current Device. Check the nameplate on the icemaker for the supply requirements.

* The main control box fuse is rated at 5A and should only be replaced by a qualified service engineer.

* The service of a licensed electrician may be required to ensure the installation is in accordance with the local codes and 

regulations.

* The wires in the mains lead are coloured in accordance with the following code:

   

 

Green & Yellow = Earth

   

 

Blue = Neutral

   

 

Brown = Live

7. WATER SUPPLY AND DRAIN CONNECTIONS

WARNING

Connect to potable cold water supply only.

* The service of a licensed plumber may be required to ensure the installation is in accordance with the local codes and 

regulations.

[Connection to the water supply

]

* The connections to the mains water supply must be made in accordance with the Plumbing Code of Australia and in 

accordance with AS / NZS 3500.1 and AS / NZS 3500.2. This appliance incorporates backflow protection complying with AS / 

NZS 3500.1. No further backflow protection is required for connection to the water supply.

* To avoid performance reduction or malfunction caused by scaling, the water supply should have a hardness of not more 

than 50 mg/L and a silica content of not more than 30 mg/L. Otherwise, installation of a proper water treatment device will be 

required.

* Water supply pressure should be minimum 0.05 MPa (0.5 bar) and maximum 0.78 MPa (8 bar). If the pressure exceeds 0.78 

MPa (8 bar), use a proper pressure reducing valve. Do NOT throttle back the supply tap.

Attach the angle end of inlet hose to the G3/4 fitting at the bottom of the ice dispenser as indicated. 

It is a wise precaution to 

have a stop valve within easy reach.

* Be sure to use the new inlet hose-sets supplied with the appliance. Do not reuse any other inlet hose-set.

* Ensure rubber tap washers are correctly positioned. Hand tighten the inlet hose sufficiently to provide a leak free joint.

Leg

Adjuster

Shorter

Longer

Содержание DCM-120KE

Страница 1: ...DCM 60KE DCM 60KE P DCM 120KE DCM 120KE P L1L009115 050818 CUBELET ICE DISPENSER INSTRUCTION MANUAL DCM 60KE Telford 70 Stafford Park 7 Telford Shropshire TF3 3BQ UK...

Страница 2: ...WATER SUPPLY AND DRAIN CONNECTIONS 5 II OPERATING INSTRUCTIONS 6 1 START UP 7 2 DISPENSING ICE 8 3 FRONT COVER 8 4 PORTION CONTROL 8 5 SWITCH LOCK FUNCTION 9 6 SHUT DOWN 9 7 PREPARING THE ICE DISPENS...

Страница 3: ...by the user Please read carefully the guidelines and warnings contained herein as they are intended to provide the installer user with essential information for the proper installation and the contin...

Страница 4: ...parts or operate the switches with damp hands This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowl...

Страница 5: ...kaging elements plastic bags and expanded polystyrene as they are potential sources of danger DCM 60 120KE DCM 60 120KE P Grille faces up or down depending on models Air Outlet Ventilation Louver Oper...

Страница 6: ...k the contents according to 2 ACCESSORIES 4 LOCATION WARNING This ice dispenser is not intended for outdoor use The ice dispenser should not be located next to ovens grills or other high heat producin...

Страница 7: ...tions The wires in the mains lead are coloured in accordance with the following code Green Yellow Earth Blue Neutral Brown Live 7 WATER SUPPLY AND DRAIN CONNECTIONS WARNING Connect to potable cold wat...

Страница 8: ...ast 3 minutes before restarting the ice dispenser to prevent damage to the compressor Periods of 5 to 6 hours without dispensing ice could result in wet ice or an ice bridge forming in the storage bin...

Страница 9: ...60 120KE P Min 7 cm Min 12 cm Place in round centre Min 7 cm About 1 cm Operation Panel 1 Service Call Lamp red 2 Lock Lamp white 3 Ice Making Lamp white 4 Water Switch 5 Ice Water Switch 6 Ice Switch...

Страница 10: ...nsing action is available After accessing the control panel for adjustments replace the front cover in its correct position NOTICE To prevent damage to the magnet provided inside do not drop the front...

Страница 11: ...switch on the control panel The display goes off and illuminates the setting again when it is stored Then the display illuminates PORTION 7 Replace the front cover in its correct position 5 SWITCH LO...

Страница 12: ...r in its correct position 9 Move the operation switch located on the right side of the ice dispenser to the OFF position 10 Unplug the ice dispenser 11 Close the water supply tap NOTICE When restartin...

Страница 13: ...h with the solution and wipe the front cover 6 Soak the spout in the solution for more than 3 minutes Use the accessory brush to clean the water pipe B Rinse thoroughly and shake to remove surplus liq...

Страница 14: ...00 hours of operation whichever comes first and once a year afterwards Replacement of these parts is required if wear exceeds factory recommendations Their service life however depends on water qualit...

Страница 15: ...pply voltage is too low Check that voltage is in required range and ice dispenser is not sharing a single receptacle with other appliances Turn OFF operation switch and turn it ON again If error code...

Страница 16: ...2 C water 21 C Ice Production per 24h 60kg ambient 10 C water 10 C 60kg ambient 10 C water 10 C Dimensions 350mm W x 585mm D x 695 710 mm H 350mm W x 585mm D x 695 710 mm H Refrigerant R134a 0 21kg GW...

Отзывы: