![Hoshizaki C-100BAE-AD Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/hoshizaki/c-100bae-ad/c-100bae-ad_instruction-manual_2164923019.webp)
19
5. Sanitizing Procedure - Final
1) Remove the shroud and spout.
) Remove the drain cap to drain any remaining solution.
3) After all of the solution has drained, replace the drain cap in its correct position.
4) Remove the reservoir cover. Pour the sanitizing solution into the reservoir until the
solution starts to overflow into the drain pan.
5) Allow the icemaker to sit for about 10 minutes before operation.
6) Replace the spout and shroud in their correct positions.
7) Plug the unit back in. Move the power switch to the "ON" position.
8) Allow the unit to make ice using the solution. When ice stops coming out, move the
power switch to the "OFF" position and unplug the unit from the electrical outlet.
9) Remove the shroud and spout.
10) Remove the drain cap to drain any remaining solution.
11) After all of the solution has drained, replace the drain cap in its correct position.
1) Remove the reservoir cover. Using a clean container, pour water into the reservoir
until it starts to overflow into the drain pan. Replace the reservoir cover in its correct
position.
13) Remove the drain cap to drain the water.
14) After all of the water has drained, replace the drain cap and all other removed parts
in their correct positions. Ensure all components, fasteners, and thumbscrews are
securely in place. Make sure that none have fallen into the storage bin.
15) Open the water supply line shut-off valve.
16) Plug the unit back in. Move the power switch to the "ON" position and allow the
icemaker to run.
17) After 30 minutes, move the power switch to the "OFF" position. Unplug the unit.
18) Pour warm water into the storage bin to melt all of the ice, then clean the storage bin
with the sanitizing solution. Rinse thoroughly after cleaning.
19) Plug the unit back in. Move the power switch to the "ON" position to start the automatic
icemaking process.