1
D. Setup
1) Position the icemaker in the selected permanent location.
) Level the icemaker from side-to-side and front-to-rear by adjusting the feet.
E. Electrical Connection
WARNING
1. This unit requires an independent power supply. See the nameplate for
proper voltage and breaker/fuse size. Failure to use a proper breaker or fuse
can result in a tripped breaker, blown fuse or damage to existing wiring. This
could lead to heat generation or fire.
.
THIS APPLIANCE MUST BE GROUNDED:
This unit is equipped with a
3-prong grounding plug to reduce the risk of potential shock hazards. It must
be plugged into a properly grounded wall outlet. If the outlet is a -prong
outlet, it is your personal responsibility to have a qualified electrician replace
it with a properly grounded 3-prong outlet. Do not remove the ground prong
from the power cord and do not use an adapter plug. Failure to follow these
instructions may result in death, electric shock, or fire.
3. The GREEN ground wire in the factory-installed power cord is connected
to a screw on the rear panel where the cord enters the unit. If it becomes
necessary to remove or replace the power cord, be sure to connect the
power cord's ground wire to this screw upon reattachment.
4. Do not use an extension cord.
5. Make sure the power switch is off before plugging in or unplugging the unit to
reduce the risk of electric shock.
6. Do not damage the power cord. It should not be altered, jerked, bundled,
weighed down, pinched, or tangled. Such actions could result in electric
shock or fire. To unplug the unit, be sure to pull the plug, not the cord, and do
not jerk the cord.
7. To reduce the risk of electric shock, do not touch the plug or power switch
with damp hands.
• Electrical connection must be installed in accordance with applicable national, state,
and local regulations.
• Usually an electrical permit and services of a licensed electrician are required.
• The maximum allowable voltage variation is ±10 percent of the nameplate rating.
• For optional drain pump installation, refer to the instruction manual included with the
pump.