© 2005 directed electronics, inc.
37
2-4 DOOR LOCK PULSE DURATION: These settings control the pulse length of the
door lock output.
• 0.8seconds (Default): in this setting the output length is 800mS and can con-
trol the majority of vehicle door lock systems.
• 3.5 seconds: in this setting the output length is 3.5 seconds and is usually used
in European vehicles with vacuum pump operated door locks.
2-5 SINGLE/DOUBLE PULSE UNLOCK: These settings control the number of unlock
output pulses.
• Double pulse unlock OFF (default): in this setting the door lock output will pulse
1 times only.
• Double pulse unlock ON: in this setting the door lock output will pulse 2 times.
This is needed in vehicles that have driver door priority unlocking on the first
pulse and passenger unlock on the 2nd pulse.
2-6 CHANNEL 3 VALIDITY/LATCHED/LATCHED RESET WITH IGNITION/30
SECOND TIMED/SECOND UNLOCK OUTPUT/DELAYED ACCESSORY
OUTPUT: This feature is not available on this model.
2-7 CODE HOPPING™ ON/OFF: This feature is not available on this model.
Содержание 727T
Страница 4: ...ii 2005 directed electronics inc ...
Страница 42: ...40 2005 directed electronics inc ...