internal programming jumper
A 10A fuse is used as both a fuse and a program jumper. This jumper determines the
light flash output polarity. In the (+) position, the on-board relay is enabled and the
unit will output (+)12V on the WHITE wire, H1/2. In the (-) position, the on-board
relay is enabled for (-) output on the WHITE wire, H1/2. To access the jumper, remove
the sliding door from on top of the control module, as shown below.
zones
N
NO
OTTEE:: The Warn Away
®
response does not report on the LED.
Zone
Number
Trigger Type
Input Description
1
Instant trigger
Hood and/or trunk pin switches.
2
Multiplexed input
Heavy impact from on-board
Doublegurard
®
shock sensor.
3
Two-stage, progresses from warning
to full alarm
Door switch circuit.
4
Multiplexed
Optional sensor, Inputs shorter than
0.8 seconds will trigger Warn Away
®
response, while inputs longer than
0.8 seconds will instantly trigger full
alarm.
5
Two-stage (similar to zone 3)
Ignition input.
FUSE/JUMPER
(-) POSITION
FUSE/JUMPER
(+) POSITION