8. The modem is now set to the call number of the mobile telephone used. This setting is retained
after the "SMS fencealarm" has been switched off.
To test, you can call the "SMS fencealarm". The relay
1
should activate briefly with each call (green
LED
flashes).
9. In order to make the televisor operational, depending on the operating mode, the corresponding
configuration SMS (see page 5) must be sent from this mobile telephone to the "SMS fencealarm":
A SMS with the current settings is sent back as confirmation. Further numbers with switching and
configuration authorisation can be added at any time, and, in special cases, other settings and
texts can be agreed (see SMS commands).
10. If required, insert the batteries now
(do not use normal batteries !!!)
and remove the insulation plate.
The charging LED ( ) lights up.
It goes out when the batteries are
charged (after approx. 2 h).
Alarm contact NC
Alarm lamp / siren
Electric fence controller
Settings
The switchable sockets (or battery switch) need
only be connected if required. The maximum con-
figuration is shown in the above illustration. The
"SMS fencealarm" is supplied with power via the
power pack supplied or an additional rechargea-
ble battery (12V DC).
Connections
CAUTIION !!! Only connect or disconnect the
switchable sockets when the connected elec-
tric fence controller is switched off. Otherwise,
the "SMS fencealarm" may be damaged.
When these settings are used, all messages are sent to the mobile phone which made the configuration
call. The following functions are available:
- In the event of proper receipt of the mobile phone network, the GSM LED ( ) light flashes evenly
(after approx. 1min).
- Each time the system is switched on, a SMS is sent with the text "GUARD ON".
- When the alarm contact is open (no alarm activated) the red LED (
) (input 1) is not illumina-
ted. When there is mains voltage present, the red LED (
) (input 2) illuminates.
- If the alarm contact is closed, the LED (
) illuminates and the green alarm LED (
) goes
out. A SMS is sent with the text "FENCE ALARM".
- A switchable socket on the alarm bushing is normally switched off. It is switched on in the event of
a fence alarm, and the connected alarm devices are activated.
- If batteries are used, these are charged. During charging, the yellow LED ( ) illuminates.
Once the batteries have been charged, the LED goes out.
- In the event that the 230V (or the 12V) operating voltage fails, the LED (
) goes out.
If there are charged support batteries, a text message is sent with the text "230V".
- A switchable socket on the switching sleeve is also switched on after switching on. The green LED
(
) does not light up. A call from the mobile telephone used for configuration switches the
socket off LED (
) lights up. A repeat call switches it on again etc. If the electric fence unit is
operated via this socket, the unit can be switched on and off via the mobile phone during mainte-
nance work. The following text message commands also switch the sockets:
CODE WORD O1ON.
switches the socket off
CODE WORD O1OFF.
switches the socket on
- For the functional check, a text message with the content:
CODE WORD ST?
can be sent to "SMS fencealarm".
he unit then sends back a text message with the current settings.
Configurations SMS:
Send a SMS with the following characters to the alarm device.
You will find the four-digit
CODE WORD
on the printed circuit board in the alarm device.
Please pay attention to the difference between the figure "
0
" and the letter "
O
".
Generally, only upper case letters are used.
CODE WORD O1:0.I1:2.I2:4.V1:0.V2:1.S:1.PT:GUARD ON.E1:FENCE ALARM.E2:230V.
The individual commands signify:
O1:0.
Output 1 switches permanently
(switchable socket for the electric fence controller switches)
I1:2.
Debounce time input 1 = 2s
I2:4.
Debounce time input 2 = 4s
V1:0.
Alarm, when input 1 is activated
V2:1.
Alarm, when input 2 is not activated
S:1.
"Switch-on" SMS is sent
PT:GUARD ON.
Text for "switch-on" SMS
E1:FENCE ALARM.
Text for alarm SMS
E2:230V.
Text for SMS when the operating voltage fails
wall plug
transformer
or 12V DC
switchable
socket
switchable
socket