Manual Speed Calibration
There are two ways to verify that the treadmill speed is set properly. The first
way is to count the running belt revolutions per minute. At 0.5 mph, the
treadmill belt should make 4 revolutions/minute for the Alpine and Advance
500 treadmill and 4.5 revolutions per minute for the Paragon II, Quantum II,
Omega II, Advance 400, 300, & 200 treadmills. If the belt revolutions are
incorrect, adjust the speed dial located on the lower control board.
The other way to verify that the treadmill speed is set properly is to enter
Diagnostics Mode. To enter Diagnostics Mode, follow the directions below:
With the treadmill power on and the safety key in position on the console, press
and hold the Incline “+” and Speed “-“ keys for about 5 seconds to enter the
Engineering Mode Menu. The console should beep three times and Eng 0
should be displayed once in the Engineering Mode Menu.
Eng1- Hardware Test
Use to check running belt speed and deck elevation.
While in the Engineering Mode Menu, press Speed “+” or “-“ until Eng1
appears in the display.
Press and hold “Start” for three seconds to select.
Press “Start” to begin. At this time, the running belt should begin moving.
The readout in the speed window will indicate the start speed of the treadmill,
which should be 0.5 mph (+ or - .05 mph).
Use Speed “+” or “-“ to increase or decrease the speed.
Use Incline “+” or “-“ to increase or decrease the elevation.
Press and hold the “Stop” button for three seconds to return to the Engineering
Mode Menu.
45