Symptom
Possible Cause Test Procedure
Repair
If the AC voltage is miss-
ing or incorrect, check the
AC service or consult an
electrician.
Replace parts as needed.
Replace MCB. (
Reference
Motor Control Board Re-
placement
in Spare Parts
Replacement section.)
Replace drive motor.
(
Reference Optical
Disk/Digital Sensor/Drive
Motor Replacement
in
Spare Parts Replacement
section.)
Replace optic sensor.
(
Reference Optical
Disk/Digital Sensor/Drive
Motor Replacement
in
Spare Parts Replacement
section.)
No motor movement
- Upon pressing start,
console responds
normally, keys respond
normally, and eleva-
tion works but no belt
movement.
Inadequate power.
Damaged or improper wir-
ing.
Failed motor control board
(MCB).
Failed drive motor.
Failed optic sensor.
-Check for dedicated cir-
cuit (0 amp is ideal) and
check wall outlet voltage
(10 VAC)
-Make sure machine is not
on extension cord or surge
protector.
-Verify there are no pinch-
es or cuts in the power
cord, power wires motor
wires, or console cable.
-Verify the connections of
above wires and cords.
Verify power to MCB (
Ref-
erence Voltage Checks
and LED Diagnosis sec-
tion.
)
Measure voltage output
from motor. (
Reference
Voltage Checks and LED
Diagnosis section.
)