Symptom
Possible Cause Test Procedure
Repair
Place a rubber mat under
machine to reduce static
carried from carpet.
Wear cotton clothing to
reduce static on the body
or spray static guard on
clothing prior to using
machine.
Use humidifier to increase
humidity in air.
Apply silicone lubrication
(
Reference Treadmill
Deck Procedures/lube in
Maintenance section.
)
Reattach grounding wire.
If it is rough or worn in tex-
ture, replace running belt
and lubricate.
Place hand underneath
running belt and feel for
adequate silicone appli-
cation.
Inspect heart rate receiver
to insure that grounding
wire is attached.
Feel underside of running
belt. It should have a
smooth cottony feel to it.
Machine on carpet.
Nylon clothing.
Dry air in home.
Inadequate lubrication on
deck and running belt.
Improper grounding of
heart rate receiver.
Defective grounding fibers
in running belt.
Static shocks when
touching machine
Static Troubleshooting