6.6
Minimal configuration of a FG8101G01
To operate a FG8101G01 as a time reference system the following functions must be
provided at least once by an extension board in the FG8101G01: PSU, MC, TDC, SP
Note
: The MC functionality is only needed for the management (configuration and
monitoring) of the FG8101G01 and the extension boards and for the data indication on
the display of the FG8101G01. If the extension board with MC functionality is pulled out
of the FG8101G01 or fails due to a defect, then the time output of the extension boards
with SP functionality is not affected as long as one extension board with PSU and one
with TDC functionality are still operated in the FG8101G01.
6.7
Front cover
Figure 2
Figure 2 shows the various elements of the front panel:
1
… LEDs of the front panel
2
… Display of the front panel
3
… Button of the front panel
2
1
3