# 69136a
9
Thermal hazards
The following precautionary measures must be observed when operating
the LED Cube 100:
Only operate the radiation component when it is fixed securely to the
irradiation chamber.
Never leave the unit unattended when an irradiation procedure is tak-
ing place. The intensive radiation in the irradiation chamber causes the
product inside the chamber to heat up. Allow the products to cool down
before removing them.
The UV emitter must not be operated in areas with an explosive at-
mosphere.
Do not irradiate highly flammable or combustible substances in the ir-
radiation chamber.
WARNING!
The interior of the LED Cube 100 and the units being ir-
radiated can heat up during the process.
Danger from gases
Under certain circumstances, chemical vapours can be released when ma-
terials are irradiated.
The safety data sheets for the materials being irradiated must be ob-
served.
The provisions relating to materials in the workplace which are hazard-
ous to health must be taken into account.
If necessary, personnel should use breathing protection and ensure
that the workplace is sufficiently ventilated.
The air pollution in the workspace must be measured when starting
operation. If there is a high level of air pollution, a ventilation and ex-
traction system must be set up.
The commonly used UV-hardening adhesives do not release any va-
pours when irradiated with the LED Spot 100.
UV radiation promotes the production of ozone. The workspace must
therefore be sufficiently ventilated.