honle LED Cube 100 Скачать руководство пользователя страница 2

LED Cube 100 

# 69136a 

 

 

Masthead 

 
All rights reserved 

 Copyright by  

Dr. Hönle AG 

 

Lochhamer Schlag 1, 

 

82166 Gräfelfing / Munich 

 
Printed in Germany, Oktober 2013 
These Operating Instructions and excerpts thereof must not be reprinted or 
reproduced in any other manner without the explicit written permission of 
Dr. Hönle AG. 
Any kind of duplication, dissemination or storing on any form of data medi-
um that is not authorised by Dr. Hönle AG constitutes an infringement of 
prevailing copyright law, and will be prosecuted. 
Technical alterations that serve to improve the unit described, or improve 
the standard of safety, are expressly reserved – even without further notice. 
Publisher responsible for the content: Dr. Hönle AG 
Layout: Dr. Hönle AG 
 
 

 

Содержание LED Cube 100

Страница 1: ... 69136a Operating Instructions LED Cube 100 ...

Страница 2: ...out the explicit written permission of Dr Hönle AG Any kind of duplication dissemination or storing on any form of data medi um that is not authorised by Dr Hönle AG constitutes an infringement of prevailing copyright law and will be prosecuted Technical alterations that serve to improve the unit described or improve the standard of safety are expressly reserved even without further notice Publish...

Страница 3: ...rage Delivery 11 4 Startup and Operation 12 General information 12 Mechanical setup 12 Mounting the LED Spot 100 13 Connection to the LED powerdrive 13 Startup 14 Activating the external safety shutdown 14 Operation 15 Measuring intensity 16 5 Service Maintenance and Cleaning 17 Service 17 Cleaning the surface of the unit 17 6 Ordering Data for Units Replacement Parts and Accessories 18 Ordering 1...

Страница 4: ...to property is possible CAUTION indicates a possible danger If it is not avoided slight injuries may result Damage to property is possible The symbols have the following meanings This symbol indicates a danger area This symbol indicates a hot surface This symbol indicates dangerous electrical voltage The two symbols below can be found next to information regarding optimal operation of the unit and...

Страница 5: ...on chamber for a wide range of applications Fig 1 LED Cube 100 with LED Spot 100 and LED powerdrive When the LED Spot 100 and the LED powerdrive control unit are operat ed as an irradiation unit the usage and safety instructions and the hazard information in the following Operating Instructions must be strictly adhered to 65807 LED Spot 100 Operating Instructions 68013 LED powerdrive Operating Ins...

Страница 6: ... suit a huge range of ap plications by using different LED emitter components The arrange ment of the LEDs and an electronic power control ensure that the light is distributed homogeneously in side the irradiation chamber The LED Cube 100 is controlled via the LED powerdrive control unit A safety system which is acti vated on the LED powerdrive pro tects operating personnel against UV radiation th...

Страница 7: ...ments and recognised safety rules In general the following potential hazards may arise during irradiation Thermal hazards Danger from gases Danger from electrical current Danger from UV radiation see LED Spot 100 Safety Fig 2 Irradiation chamber Safety of external components The LED Spot 100 is placed on top of the LED Cube 100 The irradiation chamber is connected to the LED powerdrive control uni...

Страница 8: ... may endanger the health of the user or of third parties It may also cause damage to the unit or to other property The operator must check at regular intervals that the staff are working with a safety conscious attitude The workplace safety regulations instruct the operator to conduct an appro priate and adequate assessment of the risks which arise from the use of the units The operator must ensur...

Страница 9: ...radiated can heat up during the process Danger from gases Under certain circumstances chemical vapours can be released when ma terials are irradiated The safety data sheets for the materials being irradiated must be ob served The provisions relating to materials in the workplace which are hazard ous to health must be taken into account If necessary personnel should use breathing protection and ens...

Страница 10: ...test No warranty or liability claims may be made in the event of injury to persons or damage to property if this has arisen from one or more of the following Improper use Incorrect assembly startup and operation Operation with defective and or inoperable safety and protective equipment Failure to observe the information in the Operating Instructions re garding safety transport storage assembly sta...

Страница 11: ... powerdrive The delivered parts must be inspected for completeness and damage or other issues Any damage that has been ascertained must be documented at once and reported to the dealer or to Dr Hönle AG without delay NOTE Please dispose of the packaging material in an environ mentally responsible manner It may be possible to re use it It is recommended to keep the packaging material in case the un...

Страница 12: ...ge air openings in the housing The openings must not be covered or blocked by any for eign bodies Ventilation must be guaranteed at all times DANGER When operating the LED Cube 100 make sure that there is sufficient cooling If the unit is not cooled suffi ciently there is a risk of fire The ambient temperature and the cooling air temperature must not exceed 35 C Mechanical setup The LED Cube 100 i...

Страница 13: ...tter on the irradiation chamber and se cure with the two mounting screws Fig 5 Mounting the LED Spot 100 on the LED Cube 100 Connection to the LED powerdrive The LED Cube 100 is connected to the LED powerdrive control unit via the PLC interface SUB D 25 Switch off the LED powerdrive control unit Connect the irradiation chamber to the control unit using a cable SUB D 25 pin connection cable Fig 6 C...

Страница 14: ...ube 100 may only be operated when the ex ternal safety shutdown is activated on the PLC interface in order to protect operating personnel against UV radia tion Activating the external safety shutdown The external safety shutdown on the PLC interface must be activated on the control unit when operating the LED Cube 100 To do this set ext LEDenable to ON in the Settings menu on the LED powerdrive Se...

Страница 15: ...n chamber 2 Place the product in the irradiation chamber 3 Close the door 4 Start the irradiation procedure see Operating Instructions LED powerdrive During the irradiation procedure the blank plug on the bottom right hand corner of the door lights up 5 At the end of the required irradiation time Open the door allow the product to cool down then remove it Operation ...

Страница 16: ...the UV Meter to the LED Cube 100 Measuring the UV irradiation intensity 1 Remove the blind plug from the bottom right hand corner of the door 2 Feed the UV Meter cable through the opening in the housing 3 Place the surface sensor in the irradiation chamber Fig 9 Routing the UV Meter cable to the LED Cube 100 4 Close the door 5 Switch on the UV Meter see UV Meter Operating Instructions 6 Start the ...

Страница 17: ... the unit must be left to cool down for at least 10 minutes first Parts that are not in flawless condition must be exchanged immediately Only use original replacement and wear parts There is no guarantee that other manufacturers parts are designed and manufactured to meet the re quired standards of robustness and safety No changes may be made to the LED Cube 100 and no fittings may be added or con...

Страница 18: ...ax 49 0 89 856 08 148 E mail uv hoenle de Website www hoenle de Units Name Article Order number LED Cube 100 without LED Spot 100 and LED powerdrive 68200 Replacement parts Designation Article Order number SUB D 25 pin connection cable 66476 Operating Instructions 69136 WARNING Only original replacement parts from Dr Hönle AG may be used Safe operation of the LED Cube 100 cannot be guaranteed if p...

Страница 19: ...ectrical data See LED powerdrive Operating Instructions 68013 The LED Cube 100 is connected to the control unit via the PLC interface SUB D 25 Ambient conditions The LED Cube 100 has been developed for use inside closed rooms or buildings with the following ambient conditions Temperature 5 C to 35 C Max rel humidity 80 non condensing Dimensions and weights Electrical data Ambient conditions ...

Страница 20: ......