- 5 -
than 10mm.
3.6 Relay linkage interface
It may be for connection to the lighting device or camcorder or other devices, when the host sets
up the linkage output in three minutes, the lighting device or camcorder will be activated
immediately alarm signal is received (relay touch closes for three minutes).
4. System Setup
Notice:
The host would reply the user by message if the message sent to the host by the user is valid; the
host would give off a long beep sound if the setup by phone call is effective, two beep sounds mean
setup is invalid and please set up again.
4.1 Detector matching to the host
The wireless detector and controller inside the host have been matched with the host before
leaving the factory. The added detector(s) must be match before use. Method: Open the back cover
of the detector, adjust the oscillation resistance (4.7MHZ) and emission frequency (315MHz or
433MHz) of the detector consistently to the host.
The codes on the back of the remote controller should be same as A0-A7 on the detector, 0
means the connection of N and L/H. Set up codes from A0 to A7 at the coding area of the detector
consistent to the ones of the remote controller and other wireless detector/controller that is matched
with this host, A0 responds to the thirteen pin of 2262 code IC....D3 to the tenth pin.
Set up defense area code: set up the code from D0 to D3 consistent to this host. If the host is reset
(zero clearing), it needs to rematch, please set up all wireless detectors and controllers (see the
coding bar on the back of controller) as the above methods and then, in normal working status of the
host, press RESET button under the back cover, at this moment the BUSY indicator turns red and
makes wireless detectors emit. the BUSY indicator blinks and the host gives off beep sound, it means
the operation is not finished if no sound.