Содержание s3523

Страница 1: ...GSM SMS Alarm TMPI User Manual Ver 1 1 Date Issued 2012 10 08 ...

Страница 2: ... 1 Table of contents 1 System Introduction 2 2 Features 2 3 Installation 3 4 System Setup 5 5 Use Method 10 6 System Configurations 11 7 Technical Specifications 11 8 Trouble Shooting 12 ...

Страница 3: ... as troubled wire arrangement bad stability and easy to be damaged Well designed circuit structure user friendly operating interface and remote control embody the human oriented design concept and make your convenient and easy to use and operate the unit 2 Features 1 GSM dual frequency four frequency network are applicable all countries and regions in the world 2 Back up power ensures smooth trans...

Страница 4: ...position the emergency button and foot touch switch should be installed at the convenient positions 3 The power cable of the host should be concealed and connected in good condition good heat emission is required keep it away from flammable materials 4 Switch off the power before removing installing SIM card 5 The batteries of detectors and controller should be regularly checked and replaced in ti...

Страница 5: ...n indicator blinks and means disarming status if always lighted L7 Red indicator means the host is busy alarming sending message and calling L8 Network signal indicator at means it s in searching status if the indicator blinks with time interval of on a second it means the network signal is normal if the indicator keeps on for one second and keeps off for three seconds If not the SIM card or netwo...

Страница 6: ...oscillation resistance 4 7MHZ and emission frequency 315MHz or 433MHz of the detector consistently to the host The codes on the back of the remote controller should be same as A0 A7 on the detector 0 means the connection of N and L H Set up codes from A0 to A7 at the coding area of the detector consistent to the ones of the remote controller and other wireless detector controller that is matched w...

Страница 7: ...less defense 3 0xF0 H H L L Wireless defense 4 0xF3 H H L H Wireless defense 5 0xFC H H H L Wireless defense 6 0xFF H H H H Wireless defense 7 0xC3 H L L H Wireless defense 8 0x33 L H L H Notice It s 1 when hopping N and H it s 0 when hopping N and L it s 2 when N H and L are not hopped Example 1 set up the first defense area of 12 pin wireless detector Code on the back of the controller Setup the...

Страница 8: ...eiving an alarm 12 The host will reply the three alarm numbers by message host s status when arming disarming defense by the controller 12 Close the function of replying the alarm number by message default 21 Set up the wired defense area as open circuit alarm 21 Set as closed circuit alarm default 31 Change the password Ex change to 5678 edit and send 1234 5678 to the host 40 Inquire the preset m...

Страница 9: ...faulted contents wireless defense area 3 84 Set up the message contents of wireless defense area 4 six characters at most initial defaulted contents wireless defense area 4 85 Set up the message contents of wireless defense area 5 six characters at most initial defaulted contents wireless defense area 5 86 Set up the message contents of wireless defense area 6 six characters at most initial defaul...

Страница 10: ... means which group number is to the host and the host will reply the mobile phone by message after receiving Ex set up 21000000 as the first auto dialing alarm number and the host number is 0001 edit and send 1234 51 21000000 0001 to the host the host will reply the mobile phone by message after receiving repeat the above operations or use one message to edit several orders to finish the setup of ...

Страница 11: ...rminal occurs short circuit if you want switch to open circuit edit and send 1234 21 to the host and the host will reply the mobile phone by message after receiving if you want to switch to short circuit edit and send 1234 21 to the host and the host will reply the mobile phone by message after receiving 4 4 10 Change of the host s password When the host is in normal use edit and send 1234 31 new ...

Страница 12: ...o the mobile phone to tell the recovery of power supply and call the three alarm receiving numbers circularly 5 5 Alarm treatment In case of alarm the host will automatically start the alarm horn for 90 seconds to alert the people and meanwhile send message shows the name of the defense area and call the preset alarm receiving number and monitor the on site conditions The user may answer the phone...

Страница 13: ...the operation of code hopping or matching or rematch after resetting 3 The host has no response but only the green indicator blinks for a while after the remote controller or detector emits signal the host number is not set up or the host has not order received 4 The user couldn t receive message or call from the host the GSM SIM card has no money or has been out of the validity or the communicati...

Отзывы: