11 - 27
Straight 2 of 5 IATA
*Off
A25ENA0
On
A25ENA1
Straight 2 of 5 IATA
Message Length
Minimum (1 - 48) *4
A25MIN##
Maximum (1 - 48)
*48
A25MAX##
Matrix 2 of 5
Default All Matrix 2
of 5
Settings
X25DFT
*Off
X25ENA0
On
X25ENA1
Matrix 2 of 5
Message Length
Minimum (1 - 80) *4
X25MIN##
Maximum (1 - 80)
*80
X25MAX##
Code 11
Default All Code 11
Settings
C11DFT
*Off
C11ENA0
On
C11ENA1
Code 11 Check
Digits Required
1 Check Digit
C11CK20
*2 Check Digits
C11CK21
Code 11 Message
Length
Minimum (1 - 80) *4
C11MIN##
Maximum (1 - 80)
*80
C11MAX##
Code 128
Default All Code 128
Settings
128DFT
Off
128ENA0
*On
128ENA1
ISBT Concatenation
*Off
ISBENA0
On
ISBENA1
Code 128 Message
Length
Minimum (0 - 80) *0
128MIN##
Maximum (0 - 80)
*80
128MAX##
Code 128 Append
On
128APP1
*Off
128APP0
Selection
Setting
* Indicates default
Serial Command
# Indicates a numeric
entry
Page
Содержание XENON 1900
Страница 1: ... Xenon 1900 1902 Area Imaging Scanner User s Guide ...
Страница 14: ...CCB01 010BT Base Item Number Serial Number and Revision Information location Compliance Label location ...
Страница 62: ...2 28 ...
Страница 95: ...3 33 ESC 8 Razz or error tone to indicate a decode communication to host was unsuccessful Command Action ...
Страница 96: ...3 34 ...
Страница 124: ...4 28 ...
Страница 204: ...7 62 ...
Страница 224: ...8 20 ...
Страница 232: ...9 8 ...
Страница 237: ...10 5 9 If you ve selected the defaults during installation you can click on Start Menu All Programs Honeywell EZConfig ...
Страница 238: ...10 6 ...
Страница 284: ...12 4 CCB01 010BT Charge Base Mounting 8x32 thread x 39 in 10mm deep 2 36 in 59 84mm 3 35 in 85 09mm 2 8 in 72 1mm ...
Страница 309: ...Sample Symbols Aztec MaxiCode Micro PDF417 Package Label Test Message Test Message ...
Страница 310: ...Programming Chart 1 0 2 3 6 7 5 4 8 9 ...
Страница 312: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 Xenon UG Rev C 3 11 ...